OpeRatIOn

Settings

4.
settings
4.1

temperature

appliance type with external temperature selector
The temperature can be variably adjusted. In the delivered con-
dition, temperature selection is limited. This limitation can be
cancelled by a qualified contractor (see chapter "Installation /
Settings").
You can interrupt the heating process by setting the temperature
selector to "cold".
• Cold
I Low temperature setting, 35 °C
II Recommended setting for energy saving,
low scaling, 60 °C
III Maximum temperature setting, 85 °C
Depending upon the system, the temperatures may vary from
the set value.
appliance type with temperature selector inside the control
panel
The temperature can be freely selected by the qualified contractor
(see chapter "Installation / Settings").
Factory setting: 60 °C
4.2

rapid heating during dual circuit operation

For appliance types with dual circuit operation, the heating con-
tractor can install a pushbutton to control the rapid heat-up func-
tion remotely. If required, you can switch this on. The rapid heat-
up function switches off when the selected temperature has been
reached and will not switch on again.
16
| FCR 28 | FCR 18
5.

cleaning, care and maintenance

f Have the electrical safety of the appliance regularly checked
f
by an electrician.
scaling
f Almost every type of water will deposit lime at high tempera-
f
tures. Limescale will settle inside the appliance and affect its
function and service life. The heating elements must there-
fore be descaled from time to time. A qualified contractor
who is aware of the local water quality will tell you when the
next service is due.
f Check the taps/valves regularly. You can remove limescale
f
deposits at the tap outlets using commercially available des-
caling agents.
f Regularly activate the safety valve to prevent it from becom-
f
ing blocked e.g. by limescale deposits.
6.

troubleshooting

Fault
Cause
The water does not heat
There is no power.
up.
The temperature is incor-
rectly adjusted.
The flow rate is low.
The aerator in the taps or
shower heads is dirty or
scaled-up.
Water drips from the
The valve seat is con-
safety assembly after
taminated.
heating has stopped.
If you cannot remedy the fault, notify your heating contractor. To
facilitate and speed up your enquiry, please provide the serial
number from the type plate (no. 000000-0000-000000):
FCR
Remedy
Check the fuses/MCBs in
your fuse box.
Check the temperature
setting.
Clean or descale the
aerator or shower head.
Depressurise and isolate
the appliance from the
power supply. Request
your qualified contractor
to attend.
FCR
Nr.: 000000 - 0000 - 000000
Made in Germany
Nr.: 000000 - 0000 - 000000
Made in Germany