from the mains electricity supply after installation.
It can be disconnected by making the plug accessi-
ble or by incorporating a switch in the fixed wiring
that meets electrical installation standards.
INSTALLATION:
Before starting the installation, check that the propeller is not deformed or
damaged, that it can turn freely, and that no foreign body is lodged inside the
outer casing."
The appliance shall be installed according to the attached graphic documen-
tation.
ELECTRICAL CONNECTION:
Make sure that the voltage (V) and frequency (Hz) of the power supply corre-
spond to the values indicated on the nameplate."
On the item wiring connection, there must be double pole
switch with a minimum separation between contacts of 3
mm.
(Cable rigid or stiff-tipped 2 or 3 wires, with a minimum cross-section of 1 mm
and maximum of 1.5 mm
).
2
APPLIANCE CLASS I (LHV-190, LHV-225, LHV-350, LHV-400),
it must be connected to an efficient ground connection.
We decline any responsibility of any damage to people or
things in case of improper use.
The fan should be connected, in a permanent way, to a fixed duct
by means of a triple wire (LHV-190, LHV-225, LHV-350, LHV-400) or
two wire (LHV-160, LHV-300) with a minimum section of 1 mm
fixed installation.
The power supply cable must be placed so that no liquid or vapour can en-
ter the appliance along it. If this were not possible, the cable entry should be
sealed additionally, e.g. with silicone. Otherwise, the indicated IP rating would
not be maintained.
In the event that this appliance is not used, it is recommended that you discon-
nect it from the mains electricity supply.
To finish the installation, verify that all the connections have been done
correctly and make sure that the cables are placed correctly.
Make sure that the blades turn freely.
CLEANING AND MAINTENANCE:
• Before cleaning make sure that the appliance is not connected to the electric
network and prevent it from being reconnected by accident."
• Clean with a damp cloth regularly.
• The motor, propeller and all components should be inspected periodically
to ensure that they are not dirty and have not suffered any damage. The
frequency of inspections depends on the appliance's operating conditions.
• Remove the dirt on the propeller and the inner parts of the casing to avoid
imbalances during operation, a decrease in aerodynamic performance and
motor damage.
• The fan can be cleaned with detergent.
• The appliance does not require additional maintenance.
Always demand original spare parts for repairs.
THE MANUFACTURER reserves the right to make any technological improve-
ment or modification without prior notification.
2
for
2