Installation
Use hoses that are suitable for a pressure of at least 1 bar.
How to proceed:
 A
• BioPress 6000/10000: Shorten stepped hose adapters such that the connection opening coincide with the hose di-
ameter. This helps to avoid pressure loss.
• Push the union nuts over the stepped hose adapters, push or turn on the stepped hose adapter, and secure with the
hose clips.
• Insert the flat sealing ring or the O ring into the union nut for the black hose adapter and screw onto the pressure filter
inlet.
• Insert the flat sealing ring including the flow indicator flap for the transparent stepped hose adapter, then screw onto
the pressure filter outlet.
The cleaning effect of the pressure filter can be checked at the transparent stepped hose adapter with flow indicator
flap.
Installation
W A R N I N G
Possible death or severe injury from hazardous electrical voltage!
• Only operate the unit with the protection hood fitted.
• Ensure that the unit is installed in a flood protected position at a distance of at least 2 m from the water.
Install the unit so that it is not exposed to direct sun radiation (max. 40 ºC).
How to proceed:
 B
• Place the pressure filter in a flood protected position at a distance from the pond edge of at least 2m on firm and level
ground.
– As an alternative, the filter can also be partly buried up to approx. 5 cm below the closing clamps.
• The height difference between the filter lid and the free outlet point may be max. 2 m.
• Ensure unrestricted access to the cover to be able to carry out work on the unit.
Commissioning/start-up
W A R N I N G
Possible death or severe injury from hazardous electrical voltage!
• Prior to reaching into the water, isolate (switch off and disconnect) all units/devices used in the water.
• Isolate the device (disconnect from the power supply) before carrying out any work on it.
Attention! Never operate the unit with a water pressure of more than 0.2 bar!
How to proceed:
 C
Important:
• Switch the pump on first, then the UVC clarifying unit.
• Do not operate the unit without water flowing through.
• The unit switches on automatically when power connection is established.
Switching on: Connect power plug to the socket.
• The control lamp is lit.
• The flow indicator flap in the transparent stepped hose adapter in the outlet moves.
Note:
• After a new installation, the unit only reaches its full biological cleaning effect after a few weeks.
• The full effect on bacteria is only reached as from a water temperature of + 10 °C.
• In the event of overheating, the installed temperature monitor switches the UVC lamp off automatically, the lamp
automatically switches on again once cooled down.
Check all connections for leaks.
Switching off: Disconnect the power plug.