Download Inhoudsopgave Inhoud Print deze pagina

Maintenance; Keep Ventilation Slots Clean - Rodia NS125 Gebruiksaanwijzing

Inhoudsopgave

Advertenties

Beschikbare talen

Beschikbare talen

6. MAINTENANCE

3. MOTOR
The rotor and stator in the motor are the core of the hammer drill. Do not scratch
the surface of the windings in the motor, and never apply oil or water on it.
Penetration of dust into the motor will lead to machine failure. The motor should be
cleaned after every 50 hrs of operation by blowing compressed air through the
ventilation slots while the machine is running at no load speed.

4. KEEP VENTILATION SLOTS CLEAN

Ventilation slots should be kept open and clean at all times. Clogged slots
prevent proper cooling of the motor and will lead to damages.
5. STORAGE
Store the machine in a dry place and out of reach of children.
6. FAILURE & REPAIR
Do not attempt to repair the machine yourself, this may lead to unreparable
damages or injuries.Repair and maintenance should be performed by qualified
personell only.