Problem
Water flows on the rear
plate of the refrigerator.
Water flows into the re-
frigerator.
Water flows on the
ground.
The temperature in the
appliance is too low.
The temperature in the
appliance is too high.
Replacing the bulb
If you want to replace the bulb, do these
steps:
1. Break the circuit of the appliance.
2. Press on the rear hook and at the same
time slide the cover in the direction of
the arrow.
3. Replace the bulb with one of the same
power and specifically designed for
household appliances. the maximum
power is shown on the light bulb cover)
4. Replace the light cover by sliding it into
its original position.
5. Reconnect the appliance.
6. Open the door and check if the light
comes on.
All manuals and user guides at all-guides.com
Possible cause
The product temperature is too
high.
The room temperature is too
high.
During the automatic defrosting
process, frost defrosts on the
rear plate.
The water outlet is clogged.
Products prevent that water
flows into the water collector.
The melting water outlet does
not flow in the evaporative tray
above the compressor.
The temperature regulator is not
set correctly.
The temperature regulator is not
set correctly.
The door is not closed correctly.
The product temperature is too
high.
Many products are stored at the
same time.
There is no cold air circulation in
the appliance.
Let the product temperature de-
crease to room temperature be-
fore storage.
Decrease the room temperature.
This is correct.
Clean the water outlet.
Make sure that products do not
touch the rear plate.
Attach the melting water outlet to
the evaporative tray.
Set a higher temperature.
Set a lower temperature.
Refer to "Closing the door".
Let the product temperature de-
crease to room temperature be-
fore storage.
Store less products at the same
time.
Make sure that there is cold air cir-
culation in the appliance.
Closing the door
1. Clean the door gaskets.
2. If necessary, adjust the door. Refer to "In-
stallation".
3. If necessary, replace the defective door
gaskets. Contact the Service Center.
17
Solution