RCD TEST
A
B
C
D
A. Insert the plug into the power outlet.
B. Press the "RESET" button; the indicator light turns red.
NOTE: If the indicator light is not on, the test has failed.
C. Press the "T" button; the indicator light turns off.
NOTE: If the indicator light is not off, the test has failed.
D. Press the "RESET" button, the indicator light turns red.
E. Unplug the pump, and the pump is ready for use.
WARNING: RISK OF ELECTRIC SHOCK. The RCD plug
must be tested before each use.
WARNING: Do not use the pump if this test fails. Please contact
your local Bestway Customer Service.
WARNING: Insert the RCD plug into a residual current device
(RCD) having a rated residual operating current not exceeding
30mA.
WARNING: Before inserting plug into a power outlet, make
sure the current rate of the power outlet is suitable for the pump.
IMPORTANT: DO NOT DRY RUN THE FILTER PUMP –
Make sure both the pool's Inlet and Outlet valves are fully
covered by water before operating the Filter Pump.
PUMP MAINTENANCE
CAUTION: YOU MUST ENSURE THE FILTER PUMP IS
UNPLUGGED BEFORE ANY MAINTENANCE BEGINS OR
SEVERE RISK OF INJURY OR DEATH EXISTS.
1) Unplug the Filter Pump.
2) Stop water flowing to the Filter Pump refer to pool's manual.
3) Unscrew the Filter Cap Retainer and remove the Filter Cap.
4) Clean the Filter Cartridge with a garden hose.
5) Insert the cleaned (or new) Filter Cartridge; ensure it is centered in the Filter Pump.
6) Check that the Filter Cap Seal is in place.
7) Replace the Filter Cap and screw the Filter Cap Retainer into position.
8) Open the valve A and B.
9) Follow the Pump Installation Directions section to prepare the system for use.