1. Safety Guidelines
1. Follow the installation instructions.
2. Use the appliance
•
according to its intended use
•
in good condition
•
with due regard to safety and risk of danger.
3. Note that the appliance is exclusively for use in the
applications detailed in these installation instruc-
tions. Any other use will not be considered to com-
ply with requirements and would invalidate the
warranty.
4. Please take note that any assembly, commission-
ing, servicing and adjustment work may only be
carried out by authorized persons.
5. Immediately rectify any malfunctions which may
influence safety.
2. Functional description
Hard or medium-hard drinking water contains large
amounts of lime, which can deposit in pipes, fittings
and devices and result in irreparable damages.
The water treatment device is based on the simple ex-
change of salts. Calcium ions are replaced by other ion
pairs.
3. Application
Water temperature
Ambient temperature
Operating pressure
4. Technical data
Nominal pressure
Flow rate at ∆p= 0,8 bar
Supply voltage (ext. transfor-
mer)
Protective extra low voltage 24 V
Power consumption
Safety class
Connection size
Drain connection
Model
Resin
Waste water, re-
volu-
generation water
me (l)
(l/regeneration)
PW60-A 4
30
PW60-B 10
59
This is a legacy product document
supported by Resideo. It is no longer
manufactured.
www.honeywell.com
5 - 30 °C
2 - 40 °C
2 - 6 bar
PN 10
3
2,8 m
/h (wellness mode)
230 V / 50 Hz
2 W (during conditioning)
IP 22
1" AG
1/2" hose nozzle
Salt/magnesium
consumption
(g/regeneration)
790
1980
GB
5. Scope of delivery
KaltecCool consists of:
•
Cabinet in modern, space-saving design
•
Flow controlled electronic regeneration automa-
tics with time priority control, holiday control.
•
Status indicator and control panel
•
Control valve element
•
Flask with monodisperse ion exchanger resin
•
External transformer; the device is only fed with a
protective low voltage of 24 V
•
Two armoured hoses with matching piece to
DA74C
6. Options
PW60-A = Use in detached houses
PW60-B = Use in two to three family houses
7. Assembly
•
In order to protect the device against foreign
particles, it must only be installed with an upst-
ream fine filter (recommended by Honeywell
FK74C)
•
In case of high inlet pressure (> 6 bar) a pressure
reducer must be installed in upstream
•
A drain connection within five meters distance or
two meters height must be available. The drain
hose must not be kinked in any way as this will
lead to an overflow of the device.
•
When using DA74C, connection in horizontal or
vertical pipelines is possible
•
All works should only be carried out by a qualified
person, in compiance with local water regulations
•
The installation location should be protected
against frost and extreme heat
•
The device is fitted with a check valve and there-
fore must not be fitted between a water heater
and the pressure relief safety valve
•
After the installation one must set time and water
hardness on the device and trigger a manual rege-
neration process
•
The device must be secured according to the
corresponding national implementation of the
standard EN 1717. For installation in Germany the
device must be secured with a pipe separator
(type Honeywell R295) or a system separator
(type Honeywell BA295) according to
DIN EN 1717 or DIN 1988/T4. With low inlet pres-
sure (< 3 bar) the use of the pipe separator is
recommended.
12