TECHNICAL SPECIFICATIONS
UNITO INFINITY JUICE·BAR Smart Water System
Dispensing water types :
Ÿ
Boiling water, Chilled water, Cold/Hot tap water, Flavored water (INFINTY
Juice· bar).
Tank capacity:
Ÿ
water, 2 Liters cold water.
Boiling time:
Ÿ
Cooling time:
Ÿ
Min./Max. mains pressure:
Ÿ
System max. safety pressure:
Ÿ
Max. hot water temperature:
Ÿ
Operation:
Operation via Electronic control knob, handle,Touch pannel.
Ÿ
Power supply :
Ÿ
Max. power consumption:
Ÿ
Standby power consumption :
Ÿ
Safety features:
Maximum temperature fuse, Safety valve(including
Ÿ
pressure relief valve , a built-in one direction valve & on/off valve).
Dimensions:
Ÿ
Weight:
Ÿ
Flow rate:
Ÿ
Max. water hardness :
Ÿ
CARE AND MAINTENANCE
Regular maintenance of the UNITO INFINITY JUICE·BAR
Smart Water System is required to prevent damage or
downtime. Service should be performed by qualified and
certified personnel only.
Warning: Disconnect the power supply from the UNITO INFINITY
JUICE·BAR Smart Water System before maintaining the unit.
Keep the UNITO INFINITY JUICE·BAR Smart Water System
Ÿ
in a dry, clean space. Minimize exposure to dust. Power
button or other controls should never be wet.
If the unit becomes wet, immediately shut it down. Wait for the
Ÿ
unit to completely dry before turning it on again.
Clean exterior surfaces of the unit with a soft, lint-free cloth.
Ÿ
Never use alcohol, paint thinner, benzene or other solvents to
clean this unit. Never use an abrasive material such as a
brush or scouring pad to clean surfaces.
Always test your cleaning solution on an inconspicuous area
Ÿ
before applying to the entire surface.
Wipe surfaces clean after applying cleaner.
Ÿ
Never expose the unit to vibration.
Ÿ
Make sure that all cabin ventilation outlets are always free
Ÿ
and clear.
In the event of mechanical/power failure or damage, do not
Ÿ
attempt to repair the system unit or wires. Call a certified
technician.
If the UNITO INFINITY JUICE·BAR Smart Water System
Ÿ
requires service, please consult a certified dealer.
Unauthorized service may void the warranty.
Close/open the system valve and safety valve every 6
Ÿ
months.
It is recommended to sanitize the unit every 6 months.
Ÿ
30
Sparkling water, Ambient water,
750 cc Sparkling. Boiling water: 4.4 Liter,
15 minutes (from 25°C to 100°C).
30 minutes (from 25°C to 3°C).
2/5 bar (200/500 kPa).
6 bar (600 kPa).
220~240VAC, 50HZ.
255 x 506.6 x 486.5 mm.
2 L/min @3bar.
TROUBLESHOOTING
Read and follow the assembly instructions. If the UNITO
INFINITY JUICE·BAR Smart Water System is not functioning,
please check troubleshooting table. If the water system is still not
working properly, disconnect power supply and contact authorized
UNITO customer service center for assistance. When calling for
assistance, please provide your product model and serial number.
Symptom
No water
flowing, the
water is
flowing too
slow
100°C.
1850 W.
The water is
2.0 W.
sputtering or
is irregular
Air/water
27 KG.
dripping from
the faucet
while
preparing
10° dH.
soda
No boiling
water
No Chilled
water
No Soda or
Soda is weak
No Flavor or
Flavor is weak
Possible Cause
Solution
- Main water supply valve is
- Turn on the main water
turned off.
supply valve.
- The water system is not
- Connect all the cable and
connected properly.
hose correctly.
- Hoses are bended.
- Straighten the hoses.
- There is limescale or dirt in
- Clean/replace the aerator.
the aerator.
- Check the filter
- Filter wrong installation.
connection.
- Check the water
pressure. It should be
above 1.0 bar. Check a
- There is no or too little
different tap. If the
water pressure.
pressure is also low there,
check the mains water tap
and contact your water
supplier.
- Normal behavior due to
- High pressure in CO2
high pressure, normally
cylinder.
when using a new cylinder.
- The boiler is turned off or
not connected to power
- Connect to power supply.
supply wall socket.
- Safety valve or main water
- Turn on the Safety valve
supply valve is turned off.
or main water supply valve.
- Faulty Safety valve(cut-
- Contact UNITO customer
off).
service.
- Follow page 15 step A to
- The boiler is not activated.
D.
- Child protect.
- Turn on APP.
- The pull-out hose is in the
-Push the pull-out hose to
wrong position.
start positon.
- The Chiller is powered off
or not connected to power
- Connect to power supply.
supply wall socket.
- Faulty function of chiller.
- Restart the system.
- Faulty
- Contact UNITO customer
cables/hoses/control knob.
service.
- The CO2 cylinder not
- Install the CO2 cylinder
installed or not installed
properly.
properly.
- Replace with a new CO2
- CO2 cylinder is empty.
cylinder.
- Change to a higher
- Soda intensity setting is
intensity level soda through
low.
the UNITO mobile APP.
- The Flavor pouch not
installed or not installed
- Reinstall the flavor pouch.
properly.
- Replace with a new
- The flavor pouch is empty.
Flavor pouch.
- Change to a higher
- Flavor intensity setting is
intensity level flavor
low.
through the UNITO App.