Connection version 1:
The 230 V AC mains is connected to the AC2 input (higher priority).
I.e. the battery is spared and the inverter is simultaneously protected against external voltage.
Only if there is no current on AC2, AC1 input switches to power supply by means of the inverter.
INVERTER
230 V
DC IN
OUT
BATTERY
230 V AC MAINS
Connection version 2:
The inverter is connected to the AC2 input (higher priority). I.e. power is primarily supplied by the
battery over the inverter (e.g. when using solar standalone systems). Only when the inverter switches
off due to deep discharge protection, the device switches to 230 V AC mains using the AC1 input.
230 V AC MAINS
INVERTER
230 V
DC IN
OUT
BATTERY
The Switching Station US-12 must be firmly (e. g. on the wall) attached. The device must
i
only be put into gear after all the connected cables have been firmly attached. While
running the device there must be no open wire ends or disconnected plugs of any kind.
Please ask authorized personnel if in doubt!
8
SWITCHING STATION
LOAD
PE
LOAD
SWITCHING STATION
LOAD
PE
LOAD
TECHNICAL SPECIFICATIONS
Input voltage
230 V AC, 50 Hz
Output voltage
230 V AC, 50 Hz
Current (max.)
12 A
Power (max.)
2,700 VA
<500ms
Switching time
Fuse
T 15 A / 250 V
Housing
Plastic
IP protection
IP 55
Dimensions
120 x 120 x 58 mm
Weight
250 g
Art. no.:
8-01-010710
ENVIRONMENTAL PROTECTION NOTE
At the end of its useful life, this product must not be disposed of together with normal
household waste, but has to be dropped off at a collection centre for the recycling of
electrical and electronic devices.
This is indicated by the symbol on the product, on the instruction manual or on the
packaging.
The materials of which this product is made are recyclable pursuant to their labeling.
With the reuse, the recycling of the materials or other forms of scrap usage you are making
an important contribution to the protection of the environment.
Please ask your local administration office for the appropriate disposal center.
Technical specifications subject to change. We assume no liability for typographical errors. V1_05/2020
Offgridtec GmbH | Im Gewerbepark 11 | D-84307 Eggenfelden
fon +49 (0) 8721 77861-87 | fax +49 (0) 8721 982 90-98 | www.offgridtec.com | info@offgridtec.com
9