Setting The Tightening Torque (65 Nm) - filtreau COMBI NEXT Handleiding

Inhoudsopgave

Advertenties

Beschikbare talen

Beschikbare talen

GB
REPLACING THE STRAINER PANEL; SEE FIGURES 1+3
Once you have determined that the strainer panel (L) is showing wear, it is important that you replace it with a new
strainer panel (L) as soon as possible. This will allow you to keep the filter operating at optimum capacity.
1. Disconnect the power supply and disconnect the piping.
2. Remove the cover (A) from the housing.
3. Make sure that the water can drain out of the filter.
4. Turn the drum (K) by hand until the mounting strip (O) and hose clips (P) are pointing upwards.
5. Now remove the screws from the mounting strip (O).
6. Disconnect the hose clamps (P).
7. Remove the drain channel (M) by unscrewing the fixing bolts on the front.
8. Now remove the strainer panel (L) and replace it with a new one.
9. Reattach the hose clamps (P) and retaining strip (O) . Then check that everything is attached correctly.
10. Put the cover (A) back on the housing.
11. Now reinsert the plug and hold the pushbutton (I) in for 10 seconds. The motor and rinse pump are now reacti-
vated.
REPLACING THE UV-C LAMP; SEE ILLUSTRATIONS 1+3
1. Disconnect the power supply and disconnect the piping.
2. Remove the cover (A) from the housing.
3. Make sure that the water can drain out of the filter.
4. Now loosen the locknut (Q) and disconnect the UV-C lamp (R) from the lamp holder (S).
5. Carefully remove the quartz glass (T) from the tip (U).
6. The quartz glass (T) can be cleaned with a suitable agent. Rinse the quartz glass (T) thoroughly after cleaning
(avoid scratches by using a soft cloth only!).
7. After cleaning, reinsert the quartz glass (T) into the tip (U). Make sure that the O-rings (V1+2) are in place again.
8. Insert the new UV-C lamp (R) into the lamp holder (S) and slide it further into the quartz glass (T).
9. Tighten the locknut (Q) hand-tight on the tip (U).
10. Replace the cover (A) on the housing and plug the power cord back in.
11. Hold the reset button (W) on the UV-C ballast for 5 sec. pressed.
ACTIVATING THE BYPASS FILTREAU COMBI NEXT; SEE FIGURES 3+4
During a treatment or in case there's a problem, the drum can be short-circuited by means of the bypass.
1. Switch off the control box (F).
2. Remove the red plugs (N) from the partition.
3. Place the plug of the circulation pump directly into a 230 V socket. (ATTENTION! The level safety device is not
working now).
# SLIPPING CLUTCH TORQUE 65 Nm; SEE FIGURES 2+3
The drive shaft is equipped with a slipping clutch, which is activated when the drum is blocked.
When activating the slipping clutch, the locknut on the drive shaft must be retightened.
See more at SETTING THE TIGHTENING TORQUE.

SETTING THE TIGHTENING TORQUE (65 Nm):

1. Remove the motor cover (J).
2. Apply a torque wrench to the M10 locknut on the drive shaft on the rear of the motor.
3. Hold the drum (K) by hand and tighten the locknut with the torque wrench.