Diagnostic Definitions

Power Data Diagnostic Event: The adapter did not receive power, or was not fully functional, for a period of
time.
1
Check the vehicle diagnostic port connections.
2
Verify the adapter is firmly plugged into the vehicle diagnostic port.
3
Review all affected driver logs for missing or incorrect data.
Engine Synchronization Data Diagnostic Event: The adapter failed to synchronize with the vehicle engine
computer to record required engine data for driver logs.
1
Check the vehicle diagnostic port connections.
2
Verify the adapter is firmly plugged into the vehicle diagnostic port.
3
Review all affected driver logs for missing or incorrect data.
Missing Required Data Elements Data Diagnostic Event: The Garmin eLog system failed to obtain one or more
required data elements when recording driver logs.
1
Check the vehicle diagnostic port connections.
2
Verify the adapter is firmly plugged into the vehicle diagnostic port.
3
Check the Bluetooth settings on the device running the Garmin eLog app, and verify the device and the
adapter are connected.
4
Check the GPS settings on the device running the Garmin eLog app, and verify the device settings allow
location positions to be shared with the Garmin eLog app.
5
Review all affected driver logs for missing or incorrect data.
Data Transfer Data Diagnostic Event: A failure occurred with the method for transferring roadside inspection
reports.
Perform the following actions:
1
Check the Bluetooth settings on the device running the Garmin eLog app, and verify the device and the
adapter are connected.
2
Verify all USB storage devices used to transfer roadside inspection reports are operating correctly.
3
If you have not performed a data backup within the previous seven days, back up your recorded Garmin
eLog data to a USB storage device.
Unidentified Driving Records Data Diagnostic Event: At least 30 minutes of unidentified driving was recorded
within the current 24 hour period, and over the previous 7 days.
• Drivers: Review and claim the unidentified driving time.
• Administrator: Review and assign the unidentified driving time to the respective drivers.
108
Diagnostic Definitions
GUID-2D9A184B-1D89-4D53-A050-43A2A774FC0E
EN-US
2
6
Revise to accomodate dezl/dezlCam with built-in eLog app. Changed bullets are noted with a draft