Download Print deze pagina

La Sommeliere CTVNE142A Gebruiksaanwijzing pagina 45

Advertenties

Beschikbare talen

Beschikbare talen

IV - EQUIPMENT
Refrigeration control
When measured temp is above (so warmer than requested), compressor should turn ON
When measured temp is below (so cooler than requested) compressor should turn OFF
Heating control (winter system)
According to initial information as soon as real temp is 2°C below the set value, heating system starts to operate. The heater is going
to stop working in winter if the surrounding temperature of the wine cabinet is or above 12℃.
Attention: the compressor and the heater strip are going to run at least 1 minutes after set on.
Fan control
The fan starts to work when the compressor or the heater works.
The fan stops to work when the compressor or the heater stops.
Alarming
The alarms will turn on 1 minute after detecting an abnomal temperature.
To stop alarm ringing: press a touch on the display (whatever the touch), the alarm will stop ringing.
Humidity turn on/off display content
To change hygrometry alarm status, press at the same time both touch "SET" and "UP" for 3 seconds.
When turn on the humidity voice alarm,on the display humidity place will display ON for seconds,this mean the humidity voice
alarm will work.
When turn off the humidity voice alarm, on the display humidity place will display OF for seconds,this mean the humidity voice
alarm will stop work。
Humidity maintenance system
The humidity regulates itself between 50-80%. But if the humidity is too low, you can use the box to lava that came with the device.
Fill with water, lava will spread moisture regularly in the basement. Be sure to fill from time to time and make sure the box is flat and
will not fall over in your basement.
Optional accessories
Customize your appliance and find our accessories from our partners, or on the
www.vinokado.com
site or our store
www.lasommeliere.com
All below accessories are compatible with the following cellars:
44

Advertenties

loading