8.2
Medium Exposure: Severe throbbing headache, drowsiness, fast heat rate.
Extreme Exposure: Unconsciousness, cardiorespiratory failure, death. The above levels of
8.3
exposure relate to healthy adults. Levels differ for those at high risk. Exposure to high
levels of carbon monoxide can be fatal or cause permanent damage and disabilities. Many
cases of reported carbon monoxide poisoning indicate that while victims are aware they
are not well, they become so disoriented they are unable to save themselves by either
exiting the building, or calling for assistance. Also, young children and household pets may
be the first effected. Familiarization with the effects of each level is important.
WARNING!
Exposure to high levels of carbon monoxide can be fatal or cause permanent damage and
-
disabilities.
9.

Service and contact

Would you like to contact us? That is possible! To ensure that we can serve our customers
as well and quickly as possible, we kindly ask you to take the following into account:
For questions about the installation, use or operation of this product:
www.lifeboxsecurity.fr
Go to
find answers to frequently asked questions, detailed installation videos and the most
recent version of the manual for your product.
Cannot find a solution on the website? Then leave a question via the product page. We
will help you as soon as possible.
10.

Specifications

Model
Type of apparatus
Power Supply
Recommend battery type
Sensor Type
Product Life
Sensitivity Setting
Standby Current
Alarm Current
Operation Ambient Condition
Storage/Transport Ambient Condition
Alarm Sound
to quickly get an answer to your question. Here you will
: DETCO270NF
: Type B
: DC 3V (2pcs alkaline battery)
: Caution: The correct operation of the Detector
is ensured using one of the following
batteries: GP GN15A or Raymax LR6
(For 3 years battery life at normal operation)
: Electrochemical
: 10 years after activation
: Conforms to EN 50291-1:2018 standard.
030PPM Without alarm before 120 minutes
050PPM Between 60 to 90 minutes
100PPM Between 10 to 40 minutes
300PPM Less than 3 minutes
: <20μA (average)
: <30mA (average)
: -10~+40℃, 30~95% non-condensing
: -20~+50℃, 10~95% non-condensing
: ≥85DB at 3m @3.2±0.5KHz pulsing alarm