Installation
Fig. B Determine the location of the filter. Provide a dry sheltered place (not in direct sunlight) and a stable flat surface
with sufficient space around for maintenance.
• NOTICE! Ensure that the filter is fully supported, level and above the water level of the pond.
• Place a suitable pump (max. pump capacity 17,500 L/h) preferably in the deepest part of the pond.
• Connect the pump to one of the inlets (a) (ø 110 mm) of the filter using a flexible socket. Close the other inlet with
the cap provided.
• NOTICE! The pipe connections (ø 110 mm) on the filter can NOT be glued, use flexible rubber sockets.
• Connect both outlets (b) (ø 110 mm) to the return line to the pond using flexible sockets.
• Connect the drain channel (c) (ø 110 mm) to a drain (e.g. sewer) using a flexible socket.
Fig. C Unscrew the plastic coupling from the bottom of the intake pipe (l) of the spray system.
• Remove the rinse pump (k) from its packaging and screw the plastic connector into the top of the rinse pump by
hand.
• Place the hole under the intake pipe (l) of the spray system and tighten the lock nut firmly.
• Place the capacitor box of the rinse pump in a safe and dry place near the filter.
• NOTICE! The rinse pump on/off switch is located on the side of the capacitor box, make sure it is switched on when
you put the system into operation.
Fig. D Connect an air pump (min. 1200 L/h, not supplied) to the quick-connection (q) of the filter using a ø 12 mm
reinforced air tube (not supplied).
• Remove the protective cap from the air stone inlet (e) and connect the transparent air tube (p).
• Install the immersion UVC (u) (check the separate user manual of the UVC for correct installation).
• Switch the pond pump on to fill the filter with water and check all connections, pipes, etc. for any leaks. Then
switch the pond pump off again.
• Check if the immersion UVC is completely underwater. The UVC may only be switched on if it is completely
submerged.
Fig. E Place the control box (h) in a safe and dry place near the filter.
• Connect the cable (f) of the floater (s) with the cable (g) of the control box. This DMX connection is watertight and
therefore sometimes difficult to fit (if required, squeeze the outside of the mating plug (f) while inserting the
other plug). Tighten the union nut hand-tight.
• Insert the plugs of the rinse pump (k), immersion UVC (u), electro motor (m) and pond pump (d) into the
appropriate sockets on the control box. See markings on the control box. Provide the cables with drip loops so
that no water can run along the cables into the control box.
• Plug the control box into the socket, making sure there is a drip loop here as well.
• Activate the system with the switch (w) on the bottom of the control box. The pond pump and UVC are now
activated
• The filter fills up to the lowest position of the floater (Filtration mode).
Fig. F The floater has three different switching positions. The lowest position is the normal Filtration Mode (pond pump
and UVC are switched on) the middle position is the Cleaning Mode (pond pump, UVC and the electro motor and
rinse pump are switched on). The highest position is the Safety mode (everything is switched off/ level protection)
This floater is set to the correct height and is not adjustable.