WARNING
Specific information for appliances with R290 refrigerant gas.
• Thoroughly read all warnings.
• When defrosting and cleaning the appliance, only use tools
recommended by the manufacturer.
• Place the appliance in a room without any continuously active
ignition sources (e.g. an open flame, switched on electric
or gas appliance).
• Do not drill through or burn.
• Install, use and store the appliance in a room with a floor
surface of at least 9 m
• This appliance contains 170 grams of R290 refrigerant gas
(see the information plate at the rear of the appliance).
• R290 is a refrigerant gas that is in accordance with the
European environmental directives. Never drill through any part
of the cooling circuit.
• If the appliance is installed, operated or stored in a room
without ventilation, the room should be made in such a way that
accumulation of refrigerant as a result of a leak is prevented.
This could lead to a fire or explosion hazard due to the ignition
of the refrigerant by an electric heating appliance, stove or other
ignition source.
• Store the appliance in such a way that mechanical failures
are prevented.
• Persons operating or working at the cooling circuit, must be
in the possession of a suitable certificate from an authorised
organisation, so that these persons are authorised to handle
refrigerants in a safe way in accordance with the specifications
that apply within the industry.
• Repairs may only be performed as recommended by the
manufacturer of the appliance. Maintenance and repairs that
require assistance from other trained personnel, must be
performed under the supervision of a person who knows how
to use combustible refrigerants.