2.1. Main 12-pole connector
Connect to UEGO CAN controller. Pin functions are as following:
Pin Nr. KMS
Colour
1
Red
2
Green
3
Black
4
Blue
5
White
6
Red
7
Black
8
White
9
White
10
Black
11
Grey
12
Yellow
2.2. Single pole connector for heater ground
Connect to chassis ground.
2.3. 3-pole (superseal) connector for power supply and signal
This supplies power and ground to the CAN controller as well as signal output from
controller to ECU. Connect as following:
Connector
Wire
pin
colour
Pin 1
Red
Pin 2
White
Pin 3
Black
__________________________________________________________
KMS Lambda controller
Part nr: 01-01-01-0010
Version 2.01
Function
12V supply
Can Low (-)
Heater ground
Ipr
H-
Ip
Ground
Can High (+)
Sensor signal
Un
H+
Vm
Function
MD35 pin nr
+ 12V
35: 12V Aux sup-
ply
Signal out
31: Lambda
signal 1
32: Lambda sig-
nal 2
Ground
23: ECU ground
kms.vankronenburg.nl
Details
Sensor calibration
Sensor heater ground
Sensor Signal
Analog signal output (type C)
Sensor reference voltage supply
Sensor heater voltage supply
Sensor reference ground
MP25 pin nr
13: 12V Lambda sup-
ply
1: Lambda signal
4: Analog aux input
25: ECU ground