8. Fault tracing
The UEGO CAN controller as a LED light for simple fault tracing. The function of the
LED light is described below:
LED function
LED continuously on
1 puls
4 pulses
5 pulses
6 pulses
__________________________________________________________
KMS Lambda controller
Part nr: 01-01-01-0010
Version 2.01
- No problem, controller is ok and ready to be
used.
- Heating of the sensor, controller is ok but cannot
be used until heating is finished.
- Sensor short to 12 volt.
- Sensor not connected.
- Heater ground not connected (pin 3 of the 12
pole connector).
kms.vankronenburg.nl