TROUBLESHOOTING
PROBLEM
The motor does not work
The motor works, but the burner does not light up
and after few seconds the heater stops
The burner lights up but after few seconds the
heater stops
The heater stops during operation
TECHNISCHE GEGEVENS:
Max. vermogen / Power
Aansluitspanning / Connection voltage
Gasverbruik / Usage
Thermisch beveiligd tot / Thermally secured to
Gasdruk / Gas supply pressure
CAUSES
No electricity supply
The safety thermostat is on
The cylinder gas tap is closed
The cylinder is empty
The nozzle is obstructed
The solenoid gas valve is not open
There is no spark
No connection with the earthing system
Defective connection between sensor and
safety device
Defective safety device
Excessive gas supply
Insufficient air flow
Insufficient gas supply due to ice formation
on the cylinder
TECNICAL DATA:
KEL-KAN 1500
1514709
15000W
220 - 240V~
1.09kg/h
80°C
700 mbar
Fig. 3
SOLUTIONS
Check the terminal board with a tester
Wait about one minute then restart
Open the gas tap
Use a new cylinder
Remove the nozzle and clean it.
Check that the solenoid valve works
Check the position of electrode
Check and connect properly
Check and connect properly
Replace the safety device
Check the pressure reducer and if required replace it
Check that the motor works properly
Check and use a larger cylinder or two cylinders connect-
ed together.
Fig. 4 Circuit diagram