User manual

MAINTENANCE
SAFETY VALVE
The safety valve (FL1) must be inspected regularly, about
4 times a year, to prevent clogging. The check is made
by turning the safety valve's knob anticlockwise, water
should then flow through the overflow pipe. If this does
not happen then the safety valve is defective and must
be replaced.
The safety valve sometimes releases a little water after
hot water has been used. This discharge is caused by
the expansion of cold water entering the water heater,
resulting in a pressure increase, whereby the safety
valve opens.
EMPTYING
1.
Turn off the power to the water heater.
2.
Shut off the cold water inlet with valve QM35).
3.
Loosen the cover of the drain valve (QM3) and install
the supplied hose connector and hose.
Turn the drain valve (QM3).
4.
During draining, air must be let into the water heater
5.
by loosening the hot water heater connection (XL4)
or opening a hot water tap. In order to ensure the
complete emptying of the water heater, the hose
connection must be completely tight and the outlet
must be below the lowest point of the water heater.
NOTE
The hose must exit below the water heater's
lowest level.
Water splashes may occur at the overflow pipe.
There is a risk of scalding.
When installed in a location that is exposed to the risk
of frost, the water heater must be emptied whenever
it is not in operation. Freezing will result in the water
heater bursting.
DEALING WITH MALFUNCTIONS
NOTE
Electrical installation and service must be car-
ried out under the supervision of a qualified
electrician, and in accordance with applicable
electrical safety regulations.
Check the installation's fuses as well as the thermostat
and mixer valve settings.
Wait a few hours without hot water usage and then
check whether the temperature level has risen. If there
is still no hot water, contact the installation engineer.
NIBE ES | GB
SERVICE
For service, contact the installer. The serial number (PF3)
(14 digits) and installation date should always be stated.
Only electrical equipment supplied by NIBE AB in
Markaryd may be used.

Installer manual

GENERAL
ES 160, ES 210, ES 300 is a series of water heaters that
are suitable for installation in, for example, a laundry or
utility room.
DESIGN
ES 160, ES 210, ES 300 consists of a steel vessel, with
a copper lining to protect against corrosion. The outer
casing is made of robust plastic. The water heater is in-
sulated with a freon-free polyurethane foam, which
provides good thermal insulation.
ES 300 have a connection for hot water circulation.
The water heater is designed and manufactured for a
maximum cut-off pressure of 9 bar.
TRANSPORT
ES 160, ES 210, ES 300 should be transported and
stored vertically in a dry place. The ES 160, ES 210, ES
300 may, however, be carefully laid on its back when
being moved into a building.
ASSEMBLY
The water heater is only designed for upright installation.
15 - 40 mm
The water heater is unscrewed from the pallet and lifted
into position.
Position ES 160, ES 210, ES 300 on a firm base that can
take the weight, preferably on a concrete floor or
foundation. Use the product's adjustable feet to obtain
a horizontal and stable set-up.
The area where the ES 160, ES 210, ES 300 is located
must be frost-proof and equipped with a floor drain.
20-55 mm
30 - 50 mm
0
R
0
R
15

Advertenties

Inhoudsopgave
loading

Inhoudsopgave