Pick up the chimney hood with at least 2 persons and lift it towards the ceiling frame. Press the suspension frame into
13
14
the ceiling frame until you hear a 'click'. Partly screw the 4 bolts (906133) into both frames. Level the island chimney
hood and then firmly tighten the 4 bolts.
Slide up the internal shaft part unto the ceiling. Do this carefully in order to prevent the chimney hood or the shafts
15
16
from being damaged. Fasten them with the 2 stainless steel screws (906035).
Install the Monoblock recirculation filter
Open the bottom plate and remove the aluminium fat filter from the chimney hood.
17
18
Place the Monoblock recirculation filter (7600055) in the opening provided.
Place the fat filter in the chimney hood again and close the bottom plate.
19
Programme the Monoblock recirculation filter
Attention! Do the programming with the motor switched off.
Programme:
Simultaneously press the + and the – keys for 5 seconds until the red LED flashes 5 times. The following functions have
now been enabled:
• The run-out time has been set to 30 minutes (instead of the default 10 minutes).
• The cleaning indicator for the Monoblock recirculation filter has been set to 200 operating hours.
The red LED will light up after 200 operating hours. This indicates that the Monoblock recirculation filter needs cleaning
(see the instructions below).
Re-programming:
Simultaneously press the + and the – keys for 5 seconds. The red LED will flash 5 times for confirmation. If the program-
ming is not carried out, the programming is automatically set after the chimney hood has been switched on 10 times.
Inactivate the programming (the motor must have been switched on):
Simultaneously press the + and the – keys for 5 seconds until the 3rd green LED flashes 5 times.
Clean the Monoblock recirculation filter
The Monoblock recirculation filter can be regenerated up to 12 times. This is done in the oven:
• Place the filter in the oven for 1 hour at 120°C. Provide sufficient fresh air in the room where the oven has been
placed, as smells can be released.
• Smells can be released when baking certain kinds of fish. In this case it is best to immediately regenerate the filter in
the oven.