Attention! Avoid damage caused by
improper use!
■
Only use the appliance with the included original
parts!
■
Keep the electrical contacts of the battery free of
dust and lubricants. Clean the contacts with a clean
cloth as required.
Connection
●
First connect the red quick-connect terminal clamp
to the positive pole (+) of the battery.
●
Then connect the black quick-connect terminal clamp
to the negative pole ( − ) of the battery.
The appliance can be fastened to the vehicle chassis
during the measurement using the magnetic strip
on the back of the appliance.
Testing a battery and generator
Select operating mode
●
Set the operating mode switch
side to 6 or 12 volts, depending on the type of
battery you are testing.
Battery test/start capability
●
If only the "Charge very low" LED lights up, the
charge level of the battery is weak. In this LED status,
the electrical voltage in 6 volt mode is approximately
5.8 volts and in 12 volt mode approximately 11.5 volts.
The battery needs to be charged.
●
If the "Half charged" LED also lights up, the battery is
around 50% charged. In this LED status, the electrical
voltage in 6 volt mode is approximately 6.1 volts and
in 12 volt mode approximately 12 volts. We recommend
charging the battery.
●
If the "Fully charged" LED also lights up, the battery
is fully charged and start capable. In this LED status,
the electrical voltage in 6 volt mode is approximately
6.4 volts and in 12 volt mode approximately 12.6 volts.
Attention! Property damage!
charging, learn about how to maintain the battery
by reading its operating instructions!
■
4
│
GB │ IE │ NI
on the appliance
Before
UAWSB 2 A1