Download Inhoudsopgave Inhoud Print deze pagina

Evaluatie Van Prestatierapport (Aop); Assessment Of Performance Report - attika 600 MAX Installatiehandleiding

Inhoudsopgave

Advertenties

DANISH TECHNOLOGICAL
Kongsvangs Alle 29, DK-8000 Aarhus C, Denmark.
CRP NANDO Notified Body #1235
Accredited to testing according to ISO/EN 17025 by DANAK, #300
In compliance with Regulation (EU) No 305/2011 of the European Parliament and of the Council of 9 March
2011
T3
(the Construction products Regulation or CPR), this Assessment of Performance Report applies to the
This Assessment of Performance Report attests that the performance of the above-mentioned construction
under AVCP system 3 with regard to the essential characteristics listed below
Essential characteristic
Clause No. - Description
A.4.7 –
Performance at nominal
heat output
A.4.9 –
Risk of fire
This Assessment of Performance Report covers only the above-mentioned essential characteristic(s). It is not an
exhaustive statement of the performance of the product. The manufacturer is entitled to declare the performance
of other essential characteristics than those mentioned above. This Assessment of Performance Report will remain
applicable as long as neither the harmonised standard, the construction product, nor the AVCP methods are
modified significantly.
24-8-2020
Jes Sig Andersen
2020.08.24 09:45:47 +02'00'
EVALUATIE VAN PRESTATIERAPPORT
INSTITUTE
www.ec.europa.eu

Assessment of Performance Report

1235-CPR-2431
construction product
Solid fuel room heater, 600 MAX intended for
residential room heating
placed on the market under the name or trademark of
Industrivej 19, DK-9900 Frederikshavn
product has been assessed in accordance with the harmonised standard
EN 13240:2001 + A2:2004
Performance
Level or class, unit(s)
Level or class of performance –
including units, where relevant
-Energy efficiency 76%
-Emission of CO 0,09%
-Emission of OGC 54 mgC/Nm3*
-Emission of NOx 69 mg/Nm3*
-Emission of dust 5 mg/Nm3*
- Clearance to combustible
T5
Rais A/S
Basis for the assessment of
performance
[Test report(s) No(s).]
300-ELAB-2431-EN covering
Rais 600 Inset appliance
[Test report(s) No(s).]
300-ELAB-2515-EN covering
600 MAX/E free-standing room
heater
Senior specialist Jes Sig Andersen
www.danak.dk
T8
32

Advertenties

Inhoudsopgave
loading

Deze handleiding is ook geschikt voor:

600 max/e

Inhoudsopgave