Fresnel and PC lens Spotlights
1000, 1200 & 2000 W
F 101
13° - 59°
Photometric
Typical values measured without wiremesh,
Lamp : 220V, 3200K, biplane:
Light Levels (lux) and Field Ø(m)
Axial intensity (Cd)
1200W
Angle
Lux
Distance (m)
8
2844
10
1820
12
1264
14
929
16
711
18
562
20
455
Light Distribution (Half Beam)
Min.Angle
Cd x 1000
200
150
100
50
2
4
Note
To convert Candelas into Lux, divide by the square of the distance (in m).
Page 14
Issue 001
Data
1000W / 26000 lm
1200W / 30000 lm
Min.Angle
Max.Angle
182000
17000
13°
59°
Ø (m)
Lux
Ø (m)
1,8
266
9,0
2,3
170
11,3
2,7
118
13,6
3,2
87
15,8
3,7
66
18,1
4,1
52
20,4
4,6
43
22,6
1000W
1200W
Cd x 1000
Max.Angle
20
16
12
8
4
10
20
30
6
F 201
12° - 61°
Photometric
Typical values measured without wiremesh
Lamp : 220V, 3200K, biplane, 2000W / 52000 lm
Light Levels (lux) and Field Ø(m)
Axial intensity (Cd)
2000W
Angle
Lux
Distance (m)
8
4375
10
2800
12
1944
14
1429
16
1094
18
864
20
700
Light Distribution (Half Beam)
Cd x 1000
Min.Angle
300
200
100
1
2
3
4
5
6
Note
To convert Candelas into Lux, divide by the square of the distance (in m).
Data
Min.Angle
Max.Angle
280000
27500
12°
61°
Ø (m)
Lux
Ø (m)
1,7
430
9,4
2,1
275
11,8
2,5
191
14,1
2,9
140
16,5
3,4
107
18,9
3,8
85
21,2
4,2
69
23,6
Cd x 1000
Max.Angle
30
20
10
10
20
30