Download Print deze pagina

Bracket Mounting (See Fig A And C) - Magnum Heating Sol Premium Installatievoorschriften

Advertenties

Beschikbare talen

Beschikbare talen

- If the supply cord is damaged, it must be
replaced by the manufacturer, its service agent
or similarly qualified persons in order to avoid
a hazard.
2. Mounting
2.1 Integrated in ceiling, put in exposed grid
(See fig A and B)
Place the cassette in the required ceiling
square. Minimum design height "H" for
dismounting, T-profile 32x15: 150 mm,
T-profile 38x24: 200 mm. NOTE! Avoid
fixing vertical bars in the T-profile where a
heating panel is to be installed. The panel
fills out the whole square.
Connect the panel

2.2 Bracket mounting (See fig A and C)

Minimum distance
Fig A
A: Ceiling 80mm
C: Obstacle 500mm
Minimum mounting distance
B: Wall
50mm
D: Floor
Mounting
Fig. 1
Bracket mounting
Fig C
Fig. 1: Minimum mounting distance
A
B
MAGNUM Sol Premium
False ceiling
to a thermostat.
1800mm
Min 1,5 mm²
Max 2100 W
When mounting in gypsum board, make sure
that the panel frame is anchored in the beam
behind. During long-term high temperatures
the strength of the board is reduced.
Measure, drill and screw the panel frame to
the ceiling.
Hook the panel brackets to the panel
frame on the ceiling
Connect the panel to a thermostat.
3. Scedule or pictures of the installation
The last page in this mounting instruction
is to be filled out and fixed adjacent to the
distribution board and it has to contain
(pictures or drawing) the locations of the
heating units distribution board and it has to
contain (pictures or drawing) the locations of
the heating units.
Mounting
Integrated in ceiling
Fig B
Ceiling
Wall, long side of the unit
Wall, short side of the unit
Obstacle
Floor
Fig. 1
Fig. 2
A
C
B
D
Min 1,5 mm²
Max 2100 W
Min.distance
[mm]
80
50
50
500
1800
Fig. 2
C
D