MAGNUM Sol Premium
Dear customer,
The ceiling panels are manufactured from high quality, durable materials. To guarantee that
your product functions optimally there are a few points of attention which are described in
the Installation Instructions. We can only offer you the full guarantee if this product is correctly
installed in accordance with the Installation Instructions. Carefully read the instructions prior to
installation and ensure that you have the correct tools and materials. The electrical installation
must be carried out by a qualified electrician in accordance with IEE Regulations.
Technical information
Art.nr. Type
610331 Sol Premium 300W
610751 Sol Premium 750W 230V
Class
: IP54
Colour
: RAL 9010
The panel can be used as an additional heater
in a bathroom. There are two ratings: 300W
and 750W. The heating panel provides mainly
radiation heating. This implies that to obtain
the same experienced temperature it is possible
to reduce the air temperature in the room,
which saves energy. Thanks to the location, the
panel is protected from any physical contact or
damage. There is no risk of being burned.
According to Commission Regulation (EU)
2015/1188 - Ecodesign requirements for local
space heaters, this product is defined as space
heater which must be regulated by a suitable
external control device. The control device
which is not part of the heating product must
be equipped with electronic room temperature
control plus week timer and at least one of the
following control options:
Room temperature control with open
window detection
Distance control
Adaptive start control
The ceiling heating panels are available for 230V
and are approved for two applications:
Ceiling mounting: Heating cassette is
directly mount to the ceiling using the
included mounting brackets.
Flush ceiling mounting: Heating cassette is
intended as a lay-in panel for exposed grid.
6
Output Voltage Amps Max temp. Measurements Weight
230V
1 .3
3.3
100
C
592 x 592 x 30mm
0
100
C
1192 x 592 x 30mm
0
1. Points of attention
- The heater(s) should only be wired by a
competent electrician, and in accordance with
existing national regulations. The appliance
should be preceded by an all pole switch in
accordance with existing regulations (not
applicable to versions with a cord and plug).
-
Mounting height above floor shall be at least
2,2 m,
lateral distance to wall shall be at least 50
mm. (See fig A)
- One or more units have to be connected to
power line with a differential circuit breaker
rated at 30 mA. The cable section has to be at
least 2,5 mm2.
- Units with cable and plug can be
interconnected using appropriate connection
materials.
- The maximum power in interconnection is
3400 W. If the units are to be extra insulated,
then this insulation must not exceed a value of
R=5 m2K/W.
- The appliance is not to be used by children
or persons with reduced physical, sensory
or mental capabilities, or lack of experience
and knowledge, unless they have been given
supervision or instruction
- Allow disconnection of the appliance after
installation, by accessible plug or a switch in the
fixed wiring, unless a switch complying with a
contact separation in all poles of at least 3 mm.
8 kg
11 kg

Advertenties