Electrical data
Hydraulic data
Range of use
Weight
The pump which does not stand on a base cannot support the weight of the pipes, which must be
supported in some other way.

4. MANAGEMENT

4.1

Storage

All the pumps must be stored in a dry covered place, with possible constant air humidity, free from vibrations and dust.
They are supplied in their original pack in which they must remain until the time of installation.
4.2

Transport

Avoid subjecting the products to needless impacts and collisions.
4.3

Weight and dimensions

The adhesive plate on the packaging indicates the total weight of the pump and its dimensions.

5. WARNINGS

The pumps must never be carried, lifted or allowed to operate suspended from the power cable; use the
handle provided.
The pump must never be allowed to run when dry.
The sealing device contains lubricant which is non-toxic but which may alter the characteristics of the water, in the case
of pure water, if the pump were to have any leaks.

6. INSTALLATION

Screw on the elbow with hosetail fitting provided in the packaging. Use a pipe tightening clamp to secure the pipe to the
fitting.
If the bottom of the trap where the pump is to be placed is particularly dirty, a raised support should be provided so as
to avoid blocking of the suction grid (Fig.1)
Totally immerse the pump in the water.
Ensure that the minimum dimensions of the trap in which it is housed are as follows:
Min. base dimensions (mm) 200x200 / Min. height (mm) 400
The dimensions of the trap must always be in relation to the quantity of water arriving and to the flow of the pump, so
as not to subject the motor to excessive starts/hour; it is strongly recommended not to exceed 20 starts/hour.
The pump must be installed in vertical position!
Model
P1 Rated absorbed power [W]
Mains voltage [V]
Mains frequency [Hz]
Current [A]
Capacitor [µF]
Capacitor [Vc]
Max. flow rate [l/min]
Max. head [m]
Max. head [bar]
Max. immersion depth [m]
Min. AUT starting height [mm]
Stopping height [mm]
AUT residual water height [mm]
Length of power cable [m]
Type of cable
Grade of motor protection
Insulation class
Liquid temperature range [°C]
according to EN 60335-2-41 for domestic use
Max. particle dimension [mm]
Max. ambient temperature [°C]
DNM GAS
Net/Gross weight approx. [kg]
ENGLISH
Table 3
6
Draining clear water
1526096
300
220-240 AC
50
1.3
8
450
125
6.5
0.65
7
115
45
2-3
10
H05 RNF
IP X8
F
0 °C / +35 °C
Ø 5
+40 °C
1'' 1/4 M
4.8 / 5.5