2

Deep discharge protection

When the battery is almost empty (only 0,9 V per cel remaining) the deep discharge
protection circuit will switch off the light. This prevents damage of the battery cells.
Warning:
!
If you don't use the torch for a long time we advise you to disconnect the cable light from
the battery pack to prevent fully discharging the battery pack, because the light head wil
use a tiny amount of power continuously for its electronic switching circuit.
Never store the battery pack uncharged for a long period. If the battery pack is
not used for a long period, we advise you first to charge the battery pack
completely. The battery pack can loose up to 15% of its charge per month.
Subsequently discharge and recharge the battery pack completely every three
months. When the battery has been stored uncharged for a long period, it can lose its
charge entirely. This can cause irreparable damage to the battery cells.
3

Connecting the light head to the battery tank

Connecting the light head to the battery pack is done by placing the special watertight
connector in the counter connector socket on the battery pack. The connection is made
with a little inward push followed by a quarter turn to the right. Disconnecting is done by
performing the same sequence in reverse.
Make sure that the connectors are completely clean and dry. When necessary, clean the
O-ring and use a little bit of silicone grease to create a perfect water tight seal.
Never use a sharp object to remove the O-ring. This could damage the O-ring groove
which might cause leakage over time.
Warning:
Never disconnect the light from the battery pack underwater! This will damage the
connector inside the battery pack!
4
Switching the cable light on and off
The Light has two switch rings; The switch ring located at the rear site is for controlling the
spot light power. The front switch ring is for controlling the flood light power.
The Light is switched on by sliding the locking clip at the switch ring backwards and then
turning the ring to the right 45°(position 1) = dim position, or 90° (position 2) = 100%
Light power.
To lock the switch ring(s), slide the locking clip backward and rotate the switch ring fully to
the left until it clicks (locks) into the locked position; the light will turn off.
! The lamp is for underwater use only. When using it above water, the lamp might
become overheated and shut down. After cooling down the lamp will reset itself
and work normally again.
6