9 Solving malfunctions and problems
Warning
− When working on the equipment, the equipment must be voltage-free.
− The electrical installation must be carried out by an electrical engineer with the relevant
training and qualifications
Signaling
Problem
LED not lit
Gun does not work
LED continually
Bad discharge
green
No discharge
LED blinks slowly
No or insufficient
or intermittently
compressed air from
green during use
the gun
LED blinks red or
Moisture in the airway High voltage parts wet due to the
no HV OK signal
HV OK-signal
overloaded
Defective gun
Table 2: malfunctions
10 Repairs
The Cleanflex Easy can only be repaired by Simco-ION.
In case of problems and / or questions, please contact Simco-ION or a Simco-ION
representative in your region.
A malfunctioning or defective Cleanflex Easy can be returned to Simco Ion for repairs by
following the RMA (Return Merchandise Authorization) procedure:
1.
RMA Request:
Fill in the Simco-ION RMA form
By entering the article number and serial number you can determine whether your
product will be repaired under warranty or if there are costs involved.
2.
Return sending:
• Pack the defective Cleanflex Easy properly;
• Display the RMA number;
• Send the package to the stated return address of Simco-ION.
CleanflexEasy_UM_9752050810_NL_D_GB_F_V2_1
What this means
No high voltage
Power supply defect
Power supply not connected
Wiring error
Compressed air pressure set too
low
Ionization component in the head
worn out
Ionization component in the head
defective or worn out
Compressed air not connected
Compressed air pressure set too
low
Defective valve
use of moist compressed air
High voltage too low
Short circuit or too much load
from HV OK signal
Internal defect
www.simco-ion.co.uk/repair
What to do about this
Restore power supply
See Ch5
Find and solve error
See Ch5
Increase the pressure
See Ch6
Repair the gun
See Ch10
Repair the gun
See Ch10
Connect compressed air
See Ch5
Increase compressed air
pressure
See Ch6
Repair the gun
See Ch10
Use dry clean compressed air
and blow through without
supply voltage
Take care for 24V high voltage
on the gun
Cancel too high load
Repair the gun
See Ch10
GB
41