with these installation instructions. The in-
staller shall be liable for any damage resul-
ting from incorrect installation.
17.2 Built-under
Do not install refrigerators, dishwashers, non-ventilated
ovens or washing machines underneath the appliance.
¡ If you fit an oven below the appliance, the worktop
must be at least 20 mm thick, in certain cases even
thicker. Observe the information in the oven installa-
tion instructions.
17.4 Preparing the units
The worktop must be level, horizontal and stable.
¡ The fitted units, including wall finishing strips, must
be heat-resistant to at least 90 °C.
¡ Niche cladding within 50 mm of the back wall must
not be combustible (e.g. tiles, stone).
17.5 Installing fixing rails
For stone work surfaces, bond the fixing rails in place.
17.6 Electrical connection
To protect the appliance, do not remove it from the
polystyrene trays until you press the appliance into the
cut-out. Never lay the appliance down flat on its side.
¡ Check the household wiring before connecting the
appliance.
¡ Make sure that projecting parts such as the mains
housing or the mains cable do not collide, e.g. with
a drawer.
17.3 Intermediate floor
If the underside of the hob can be touched, an interme-
diate floor must be fitted.
¡ Ask your specialist retailer for an intermediate floor
as an accessory.
¡ If you use your own intermediate floor, the minimum
distance to the mains connection of the appliance
must be 10 mm.
¡ Seal the cut surfaces to make them heat-resistant.
This prevents the worktop from swelling as a result
of moisture.
¡ The appliance fulfils the requirements of protection
class I and must only be operated in conjunction
with an earth conductor.
¡ In the permanent electrical installation, a partition
must be provided in the phases in accordance with
the installation regulations.
¡ If
appears on the appliance's display, it has
not been connected correctly. Disconnect the appli-
ance from the mains and check the connection.
Connecting without a pre-installed cable
Only connect the hob in accordance with the connec-
tion diagram.
¡ If required, install the enclosed copper bridges.
¡ For a 3-/2-phase connection (3 N~/2 N~), the
power cable must correspond to type H05 VV-F or a
higher rating.
¡ Use the current load to determine which wire cross-
section you require. A cross-section of < 1.5 mm² is
not permitted.
¡ For a single-phase connection (1 N~), the power
cable H05RR-F3G4 (length 1 m) is available from
customer service.
Installation instructions en