assembly
building-in dimensions wall hood
ø150/125
850-1210
235
240
206
385
600
530
900
min. 650
WS9011MM
WS1211MM
WS9011NM
GB 10
ø150/125
700-1065
60
235
240
530
900
min. 650
WG3/4K
ø150/125
765-1125
240
235
530
900
min. 650
assembly
WG3/4U
150
WG3/4V
WS1211NM
(continued)
installation wall hood
The most important dimensions are shown on the previous
page. You can set the height of the telescopic pipe. Take the
allowable tolerances into account. Position the discharge
and the electrical connection in such a way that it will be
easy to hook up the hood.
Remove the transport safety device prior to assembly, see
page 9.
marking out and fitting fixing materials
Draw a vertical centre line on the wall (centre of the
extractor hood).
Place the fastening clip against the wall so that it rests
against the ceiling. The arrow on the flanged rim indicates
the middle of the cooker hood. Mark the attachment holes to
be drilled. Drill the holes (ø 8 mm).
Put the plugs into the wall and fix the fixing bracket to the
wall with the screws supplied (5 x 50 mm).
marking out and fitting motor module
Mark the position of the underside of the hood on the wall
(bear in mind the minimum distance to the hob). Mark the
(vertical) centre line.
Fold or cut the template depending on type and mark the
20
upper fixing holes.
Drill the fixing holes (2 x ø 10 mm).
Fix the plugs. Screw two nuts onto the threaded ends in the
opposite direction. Screw the threaded ends into the wall
leaving 20 mm projecting (see illustration).
Remove the nuts.
GB 11