Certify that the equipment intended for use in potentially explosive atmospheres, only new products, indicated here after:
Are in accordance with:
-
Directive 2014/34/EU (Equipment and protective systems for use in potentially explosive atmospheres)
-
Directive 2014/30/EU (Electro Magnetic Compatibility).
-
Harmonized standards:
EN 60079-0:2012 (General rules)
This standard has been compared with EN 60079-0:2018 (Currently Harmonised) and no significant changes have
occurred which are applicable to this equipment.
EN 60079-11:2012 (Intrinsic safety "i")
EN 60079-26:2007 (Group II cat. 1G requirements)
This standard has been compared with EN 60079-26:2015 (Currently Harmonised) and no significant changes have
occurred which are applicable to this equipment.
IEC 61000-6-2: 2001 (EMC, Immunity in industrial location)
IEC 61000-6-3: 2001 (EMC, Emission in industrial location)
IEC 61000-6-4: 2001 (EMC, Emission in industrial location)
EN-ISO-IEC 80079-34:2011 (Potentially explosive atmospheres – Application of quality systems
The type (protection mode "ia") which has been the subject of;
-
EC-type Examination Certificate Numbers:
KEMA 03 ATEX1219 X, Issue 5
Delivered by the KEMA, Meander 1051, 6825 MJ Arnhem, The Netherlands, Notified Body No. 0344.
Manufacturing plant in Dwingeloo which has been the subject of;
Production Quality Assurance Notification Number:
DEKRA 12ATEXQ0041, Issue 3
Delivered by the DEKRA, Meander 1051, 6825 MJ Arnhem, The Netherlands, Notified Body No. 0344.
Date: October 1
E. Timmer
Managing Director - Klay Instruments B.V.
The marking of the equipment is as follows:
II
means that the equipment has been built for use in surface industries (and not in mines endangered
by firedamp).
1
equipment for use in Zone 0 (if G)
G
equipment for use with gas, vapours or mists
Ex
equipment in compliance with European standards for
explosive atmospheres
ia
equipment in compliance with specific building rules for intrinsically save equipment
IIC
equipment for use with gas of subdivision C
T4
equipment whose surface temperature does not exceed 135°C with < 70°C Ambient temperature.
Protection Grade, Series 8000-SAN, 8000, CER-8000, IP 66
Protection Grade, Series Hydrobar-cable, Hydrobar-EXTD, IP 66
The Hydrobar-FR and all other submersible parts from the Series Hydrobar are IP 68.
Furthermore, whatever the protection mode, only use cable glands with a protection degree of at least IP 66.
Be sure the cable diameter complies with the selected cable gland. Tighten the cable gland in a proper way.
Never forget to mount the covers of the electronics housings in a proper way.
For other technical details, refer to the instruction manuals of the series transmitters.
Nijverheidsweg 5
P.O. Box 13
EU-DOC/10-2019/12
EU-DECLARATION OF CONFORMITY
Klay Instruments B.V.
Nijverheidsweg 5, 7991 CZ Dwingeloo, The Netherlands
Electronic Pressure- and Level Transmitters
Series 8000-SAN, Series 8000, Series CER-8000
Hydrobar-Cable, Hydrobar-EXTD, Hydrobar-FR
st
, 2019
7991 CZ Dwingeloo
7991 AA Dwingeloo
Signature:
II 1G Ex ia IIC T4 Ga
Tel.: +31 521 591550
Fax.: +31 521 592046
The Netherlands