HPD
VERSCHILDRUK
TRANSMITTER
MODBUS REGISTER MAPPEN
INPUT REGISTERS
Differential Pressure
1
(Channel 1)
2
Output 1
Air Volume Flow Rate
3
High (Channel 1)
Air Volume Flow Rate
(Channel 1)
4
Air Volume Flow Rate
Low (Channel 1)
Min. Pressure Limit
5
Flag (Channel 1)
Max. Pressure Limit
6
Flag (Channel 1)
7-10
Differential Pressure
11
(Channel 2)
12
Output 2
13
Air Volume Flow Rate
14
(Channel 2)
Min. Pressure Limit
15
Flag (Channel 2)
Max. Pressure Limit
16
Flag (Channel 2)
17-20
MIW-HPD-NL-000 - 16 / 12 / 16
Data type
Description
unsigned int. Channel 1 measured differential pressure
unsigned int. Channel 1 analogue / digital output
Reserved, returns 0
unsigned int.
Channel 1 air volume flow rate in m
Channel 1 air volume flow rate in m
unsigned int.
Channel 1 air volume flow rate low word in m
The flag indicates that the pressure is over or
unsigned int.
below the channel 1 min. limit
The flag indicates that the pressure is over or
unsigned int.
below the channel 1 max. limit
Reserved, returns 0
unsigned int. Channel 2 measured differential pressure
unsigned int. Channel 2 analogue / digital output
Reserved, returns 0
unsigned int. Channel 2 air volume flow rate in m
The flag indicates that the pressure is over or
unsigned int.
below the channel 2 min. limit
The flag indicates that the pressure is over or
unsigned int.
below the channel 2 max. limit
Reserved, returns 0
terug naar inhoudstafel
Data
HPD-X-1K0
HPD-X-2K0
HPD-X-4K0
HPD-X-10K
/h
HPD-X-10K0
3
HPD-X-1K0
3
/h
HPD-X-2K0
HPD-X-4K0
/h
HPD-X-10K0
3
HPD-X-1K0
HPD-X-2K0
HPD-X-4K0
HPD-X-10K
HPD-X-1K0
HPD-X-2K0
/h
3
HPD-X-4K0
HPD-X-10K
www.sentera.eu
Values
0—10.000
1.000 =
0—20.000
1.000 =
0—40.000
1.000 =
0—10.000
1.000 =
0— 1.000
100 =
HPD-X-1K0/2K0/4K0
0—100.000
1.000 =
0—31.623
0—44.721
0— 63.245
1.000 =
0—100.000
0 =
over the limit
1 =
below the limit
1 =
over the limit
0 =
below the limit
0—10.000
1.000 =
0—20.000
1.000 =
0—40.000
1.000 =
0—10.000
1.000 =
0— 1.000
100 =
0—31.623
0—44.721
1.000 =
0— 63.245
0—100.000
0 =
over the limit
1 =
below the limit
1 =
below the limit
0 =
over the limit
100,0 Pa
100,0 Pa
100,0 Pa
1.000 Pa
10,0 %
1.000 m
/h
3
1.000 m
3
/h
100,0 Pa
100,0 Pa
100,0 Pa
1.000 Pa
10,0 %
1.000 m
/h
3
10 - 12