OPTISONIC 8300
9.11.8 Device Root Menu (Hoofdmenu Toestel)
Quick Setup (snelle setup)
Quick Setup (snelle setup)
Quick Setup (snelle setup)
Quick Setup (snelle setup)
Quick Setup
Detailed setup (gedetailleerde configuratie)
Detailed setup (gedetailleerde configuratie)
Detailed setup (gedetailleerde configuratie)
Detailed setup (gedetailleerde configuratie)
Process Input (procesingang)
Calibration (kalibratie)
Filter
Plausibility
Simulation (Simulatie)
Informatie
Opt
VoS monitor
(geluidssnelheid
monitoren)
Linearization (linearisatie) Linearization / Dynamic Viscosity
Opt
General
(algemeen)
Opt
P&T Correction
(P&T
correctie)
Diagnosis Value
(diagnosewaarde)
HART
I/O
Hardware
Opt
Current Output A/B/C
(stroomuitgang)
Frequency Output
(frequentie-uitgang)
Opt
A/B/D
Opt
Pulse Output A/B/D
(pulsuitgang)
02/2020 - 4003604702 - MA OPTISONIC 8300 nl R03
BESCHRIJVING VAN DE HART-INTERFACE
Language / Tag / Polling Address / <Reset Errors>
Reset Counter 1 / Reset Counter 2 / Reset Counter 3
Meter Size / <Zero Calibration> / GK
Minimum Limit / Maximum Limit / Flow Direction / Time Constant /
Threshold Low Flow Cutoff / Hysteresis Low Flow Cutoff
Error Limit / Counter Decrease / Counter Limit
<Simulation Volume Flow> / <Simulation Velocity of Sound>
<Sensor CPU> / <Sensor DSP> / <Sensor Driver> / <Calibration Date> /
<Calibration Date> / Serial Number Sensor / V Number Sensor
Monitor Velocity of Sound
Opt
Opt
Opt
Opt
Monitor Settings
Monitor Settings
Monitor Settings
Monitor Settings
Matching Factor / Actual Ratio Measurement/Calibration / <New Match?> /
VoS Tolerance / Time Constant
Adiabatic Index
P&T Correction / <Set P&T Correction> / P&T Inputs
Opt
Pipe Pressure
/ Density
Diagnosis 1 / <Set Diagnosis 1> / Diagnosis 2 / <Set Diagnosis 2> / Diagnosis 3 /
<Set Diagnosis 3>
Sensor serienr. / <HART eenheden uitlijnen>
Actual Flow, Corrected Flow
Actual Flow, Corrected Flow
Actual Flow, Corrected Flow
Actual Flow, Corrected Flow
Unit / Format / Upper Sensor Limit / Lower Sensor Limit / Minimum Span
Klemmen A / Klemmen B / Klemmen C / Klemmen D
Cust
Range 0%
/ Range 100%
Cust
Error Current
/ Error Condition
Cust
Range Max
/ Polarity
Cust
LFC Threshold
/ LFC Hysteresis
Threshold Range Change
<Simulation>
Opt, Cust
Pulse Shape
/ Pulse Width
Cust
Range Min
/ Range Max
Cust
Limitation Max
/ LFC Threshold
Cust
Invert Signal
/ Special Function
<Simulation>
Opt, Cust
Pulse Shape
/ Pulse Width
Rd, Cust
Pulse Value Unit
/ Value Per Pulse
Cust
LFC Hysteresis
/ Time Constant / Invert Signal
Opt, Cust
Phase Shift
/ <Information> / <Simulation>
www.krohne.com
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
, Enthalpy Flow
Enthalpy Flow
Enthalpy Flow
Enthalpy Flow
, Mass Flow ,
, Mass Flow ,
, Mass Flow , ...
, Mass Flow ,
Cust
/ Extended Range Min
Cust
/ Measurement
Cust
Cust
/ Limitation Min
/ Limitation Max
Cust
/ Time Constant
Opt, Cust
/ Hysteresis Range Change
Opt, Cust
/ 100% Pulse Rate
Cust
Cust
/ Polarity
/ Limitation Min
Cust
/ LFC Hysteresis
Opt, Cust
/ Phase Shift
Opt, Cust
/ Max. Pulse Rate
Cust
/ Polarity
Opt
Opt
Opt
/ Pipe Temperature
Cust
/ Extended Range Max
Cust
Cust
/ Range Min
Cust
/
Cust
/ Special Function
Opt, Cust
/ <Information> /
Opt, Cust
/ Measurement
Cust
/
Cust
/ Time Constant /
Opt, Cust
/ <Information> /
Opt, Cust
/ Measurement
Cust
/ LFC Threshold
Cust
Opt, Cust
/ Special Function
9
/
Cust
/
/
Cust
/
Cust
/
Cust
/
Cust
/
/
131