HOOFDSTUK 6 – PROBLEEMOPLOSSING
PROBLEEM
SLECHTE DRAADAANVOER
KORTE INSCHAKELDUUR
CONTACTTIP
OVERVERHITTING TOORTS
SLECHTE WERKING
SCHAKELAAR
LAS POREUS
MOGELIJKE OORZAAK
•
LINERBUIS VERSTOPT OF GEKNIKT
•
INCORRECT FORMAAT LINER OF CONTACTTIP
•
LINER TE KORT AFGESNEDEN EN NIET OP DE JUISTE MANIER GEZETEN IN DE GASVERSPREIDER
•
AANDRIJFROLLEN TE STRAK MET ALS GEVOLG AFSCHURING VAN HET LASDRAAD
•
LASDRAAD VUIL, VERROEST OF OVERMATIG GEGOTEN
•
AANDRIJFROLLEN TE STRAK MET ALS GEVOLG AFSCHURING VAN HET LASDRAAD
•
LASDRAAD VUIL, VERROEST OF OVERMATIG GEGOTEN
•
GEBRUIK VAN DRAAD ZONDER COATING, WAARDOOR SLIJTAGE VERHOOGT
•
ONJUIST FORMAAT CONTACTTIP
•
TE HOGE BEDRIJFSDUUR INGESCHAT VOOR TOORTS
•
KLEMSCHROEF LOSMAKEN OP QUICK CONNECT BLOK
•
ONVOLDOENDE FORMAAT ELEKTRICITEITSKABEL EN/OF AARDEKABEL
•
CONNECTORCONUSSEN EN/OF CONUSMOEREN LOSMAKEN
•
TOORTS WORDT BEDIEND MET EEN STROOMSTERKTEBEREIK HOGER DAN ZIJN BEREIK
•
SLECHTE ELEKTRISCHE WERKING IN STROOMBRON
•
SLECHTE VERBINDING VAN KABELS MET SCHAKELKLEMMEN
•
SPATTEN OPGEBOUWD TUSSEN HENDEL EN SCHAKELAARKAST
•
CONTACTEN VAN SCHAKELAAR VUIL
•
SCHROEVEN VAN SCHAKELAARKAST LOS
•
GEBROKEN OF VERSLETEN SCHAKELAARKABEL
•
SPATTEN OPGEBOUWD IN BLOKKERINGSGAS MONDSTUK
•
LEKKEN IN GASSLANG OF ONJUISTE AANSLUITING
•
O-RINGEN OP ELEKTRICITEITSPEN ZIJN GEBROKEN OF BESCHADIGD
•
BINNENBUIS LOS VAN DE CONNECTORCONUS
•
SLECHTE DRAADAANVOER (ZIE BOVEN)
•
INCORRECT SCHERMGAS OF LASDRAAD
•
VERROESTE OF SLECHTE KWALITEIT VAN LASDRAAD
•
OUDERMETAAL VERROEST OF BESMET OF HOGE ZWAVELCONTENT
•
ONJUISTE STROOMINSTELLING