Bausch Datacom –InduBox PSTN III – referentiehandleiding – V1.0c
A.
EC-conformiteitsverklaring
standard CE +
TST25-3 (additional extended immunity tests)
EN61000-3-2 Electromagnetic compatibility, part 3, section 2
Limits for harmonic current emissions.
EN61000-3-3 Electromagnetic compatibility, part 3, section 3
Limitations of voltage fluctuation and flicker.
EN61000-4-2 Electromagnetic compatibility, part 4, section 2
Electrostatic discharge immunity test.
CISPR24 : 4 KV contact / 8 KV air
TST25-3 : 8 KV contact (20 +/- contacts) / 15 KV air (20 +/- discharges)
EN61000-4-3 Electromagnetic compatibility, part 4, section 3
Radiated fields immunity test.
CISPR24 : 10 V/m 80 MHz - 2000 Mhz, mod. AM 80% 1KHz
TST25-3 : 30 V/m 80 MHz - 2000 Mhz, mod. AM 80% 1KHz
ENV50204 Electromagnetic compatibility, Basic immunity standard, Radiated
Electromagnetic field from digital radio telephones immunity test.
CISPR24 : 10 V/m 890-2400 MHz, 1% freq step, 1s dwell, 50% duty,
200 Hz repetition time
TST25-3 : 30 V/m 890-2400 MHz, 1% freq step, 1s dwell, 50% duty, 200 Hz repetition
time
EN61000-4-4 Electromagnetic compatibility, part 4, section 4
Electrical fast transient/burst immunity test.
CISPR24 : 0.5 KV and 1 KV 5/50 ns, 5 Khz rep. freq on AC mains
TST25-3 : 2 KV and 4 KV, 5/50 ns, 5 Khz rep freq on AC mains
EN61000-4-5 Electromagnetic compatibility, part 4, section 5
Surge immunity test.
CISPR24 : 10 pulses 1 KV 1,2/50 µs (5+ 5-) on AC mains
TST25-3 : 6 KV pulses
EN61000-4-6 Electromagnetic compatibility, part 4, section 6
Conducted immunity test.
2013 / 04 / 03
21
InduBox PSTN III V1.0c NL