Bausch Datacom –InduBox GSM IX – ref. handleiding – V2.0b
A.
EC-conformiteitsverklaring
According to the provisions of the 1999/5/EC Directive, covering all essential requirements (EMC-directive) Bausch
Datacom NV/SA, Tiensesteenweg 54-56, 3360 Korbeek-Lo, herewith takes the sole responsibility to confirm that the
product Indubox GSM IX which refers to this declaration, is in accordance with the following standards or
standardized CE/EM documents: CE / EMC and TST25-3 (additional extended immunity tests)
CE / EMC
TST25-3 (additional extended immunity tests)
EN61000-3-2
Electromagnetic compatibility, part 3, section 2
Limits for harmonic current emissions.
EN61000-3-3
Electromagnetic compatibility, part 3, section 3
Limitations of voltage fluctuation and flicker.
EN61000-4-2
Electromagnetic compatibility, part 4, section 2
Electrostatic discharge immunity test.
CISPR24 levels : 4 KV contact / 8 KV air
--> 8 KV contact / 15 KV air
EN61000-4-3
Electromagnetic compatibility, part 4, section 3
Radiated fields immunity test.
CISPR24 levels : 3 V/m 80 MHz - 1000 Mhz, mod. AM 80% 1KHz
--> 10 V/m
EN61000-4-4
Electromagnetic compatibility, part 4, section 4
Electrical fast transient/burst immunity test.
CISPR24 levels : 0.5 KV +/- 50 V and 1 KV +/- 10 V on AC mains
--> 2 KV and 4 KV
EN61000-4-5
Electromagnetic compatibility, part 4, section 5
Surge immunity test.
CISPR24 levels : 0.5 KV +/- 50 V and 1 KV +/- 10 V on AC mains
--> 2 KV
EN61000-4-6
Electromagnetic compatibility, part 4, section 6
Conducted immunity test.
CISPR24 levels : 3 V 0.15 MHz - 80 MHz, mod. 80% at 1 KHz
--> 10 V
EN61000-4-8
Electromagnetic compatibility, part 4, section 8
Power frequency magnetic field immunity test.
CISPR24 levels
EN61000-4-11
Electromagnetic compatibility, part 4, section 11
Voltage dips, short interruptions and voltage variations immunity
test.
CISPR24 levels
ENV50204
Electromagnetic compatibility, Basic immunity standard, Radiated
Electromagnetic field from digital radio telephones immunity test.
CISPR24 levels : 3 V/m 890-1000 MHz / 1700-2000 MHz, mod.
100% 200Hz
--> 10 V/m
EN55022 (1994)+A1(1995)+A2(1997)
disturbance characteristics of ITE-equipment.
EN55022 class B limits
Radiated emission : 30 - 1000 MHz
conducted emission : 0.15 - 30 MHz
EN55024
performance criteria for immunity tests
EN61000-6-3
performance criteria for emission tests
2013 / 04 / 02
(4KV and 6 KV)
(30 V/m)
on
890 - 1000 MHz
Limits and methods of measurement of radio-
32
InduBox GSM IX V2.0b NL