Download Inhoudsopgave Inhoud Print deze pagina

FASTERHOLT FM4400 Gebruiksaanwijzing pagina 22

Beregningsmachine
Inhoudsopgave

Advertenties

MACHINEGEGEVENS
Cons
Note
Fact.
no.
Adj.
40
0
41
0.50
42
0.20
43
3.5
44
0.2
Min.
Max.
Description
Value
Value
0
2
Analog Pressure gauge
0 = Digital Switch
1 = Analog Pressure gauge - Display units [BAR]
2 = Analog Pressure gauge - Display units [PSI]
0.10
5
Voltage Offset [V]
0.05
5
Voltage gain [V]
0.0
25.0
Pressure setpoint 0.0 - 25.0 [BAR]
Pressure level for Off - On
0.2
25.0
Pressure hysteresis 0.2 - 25.0 [BAR] *
Setpoint - 0.5 * hysteresis for Off
Setpoint + 0.5 * hysteresis for On
Default Settings 0.2
• 3.4 BAR = Off
• 3.6 BAR = On
22