9 Technische gegevens
R5T, R8T
Thermistor warm tapwater
R6T
* Externe binnen- of
buitenomgevingsthermistor
R7T
Gemengd aanvoerwaterthermistor
S1S
# Contact elektrische voeding met kWh-
voorkeurtarief
S2S
# Impulsingang 1 elektrische meter
S3S
# Impulsingang 2 elektrische meter
S6S~S9S
* Digitale ingangen vermogensbeperking
SS1 (A4P)
* Keuzeschakelaar
TR1
Voedingstransformator
X6M
# Klemmenblok elektrische voeding back-
upverwarming
X*, X*A, X*H*,
Connector
X*Y
X*M
Klemmenblok
* Optioneel
# Ter plaatse te voorzien
Vertaling van tekst op bedradingsschema
Engels
(1) Main power connection
For preferential kWh rate power
supply
Indoor unit supplied from outdoor Binnenunit gevoed door buiten
Normal kWh rate power supply
Only for normal power supply
(standard)
Only for preferential kWh rate
power supply (outdoor)
Outdoor unit
Preferential kWh rate power
supply contact: 16 V DC
detection (voltage supplied by
PCB)
SWB
Use normal kWh rate power
supply for indoor unit
(2) Backup heater power supply
Only for ***
(3) User interface
Only for LAN adapter
Only for remote user interface
(5) Ext. thermistor
SWB
(6) Field supplied options
12 V DC pulse detection (voltage
supplied by PCB)
Installatiehandleiding
30
Vertaling
(1) Aansluiting
hoofdstroomtoevoer
Voor elektrische voeding met
kWh-voorkeurtarief
Elektrische voeding met normaal
kWh-tarief
Alleen voor normale voeding
(standaard)
Alleen voor elektrische voeding
met kWh-voorkeurtarief (buiten)
Buitenunit
Contact voor elektrische voeding
met kWh-voorkeurtarief: 16 V-
gelijkstroomdetectie (spanning
geleverd door printplaat)
Schakelkast
Gebruik elektrische voeding met
normaal kWh-tarief voor
binnenunit
(2) Elektrische voeding back-
upverwarming
Alleen voor ***
(3) Gebruikersinterface
Alleen voor de LAN-adapter
Alleen voor de
afstandsgebruikersinterface
(5) Externe thermistor
Schakelkast
(6) Niet meegeleverde opties
12 V-
gelijkstroompulsdetectie (spannin
g geleverd door printplaat)
Engels
230 V AC supplied by PCB
Continuous
DHW pump output
DHW pump
Electrical meters
For safety thermostat
Inrush
Max. load
Normally closed
Normally open
Safety thermostat
Safety thermostat contact: 16 V
DC detection (voltage supplied
by PCB)
Shut-off valve
SWB
(7) Option PCBs
Alarm output
Changeover to ext. heat source
Max. load
Min. load
Only for demand PCB option
Only for digital I/O PCB option
Options: ext. heat source output,
alarm output
Options: On/OFF output
Power limitation digital inputs: 12
V DC / 12 mA detection (voltage
supplied by PCB)
Space heating On/OFF output
SWB
(8) External On/OFF thermostats
and heat pump convector
Additional LWT zone
Main LWT zone
Only for external sensor (floor/
ambient)
Only for heat pump convector
Only for wired On/OFF
thermostat
Only for wireless On/OFF
thermostat
Vertaling
230 V wisselstroom geleverd
door printplaat
Continue stroom
Uitgang pomp voor warm
tapwater
Warmtapwaterpomp
Elektriciteitsmeters
Voor veiligheidsthermostaat
Inschakelstroomstoot
Maximale belasting
Normaal gesloten
Normaal geopend
Veiligheidsthermostaat
Contact voor de
veiligheidsthermostaat: 16 V-
gelijkstroomdetectie (spanning
geleverd door printplaat)
Afsluiter
Schakelkast
(7) Optionele printplaten
Alarmuitgang
Omschakeling naar externe
warmtebron
Maximale belasting
Minimale belasting
Alleen voor optie vraag-printplaat
Alleen voor optie digitale I/O-
printplaat
Opties: uitgang externe
warmtebron, alarmuitgang
Opties: uitgang AAN/UIT
Digitale inputs
vermogenbeperking: 12 V-
gelijkstroom-/12 mA-
detectie (spanning geleverd door
printplaat)
Uitgang ruimteverwarming AAN/
UIT
Schakelkast
(8) Externe AAN/UIT-
thermostaten en
warmtepompconvector
Aanvoerwatertemperatuur
secundaire zone
Aanvoerwatertemperatuur
primaire zone
Alleen voor ext. sensor (vloer of
omgevings)
Alleen voor
warmtepompconvector
Alleen voor Aan/UIT-thermostaat
met draad
Alleen voor draadloze Aan/UIT-
thermostaat
EHFZ03S18DJ3V
Daikin Altherma 3 R F
4P596818-1 – 2019.10