Download Inhoudsopgave Inhoud Print deze pagina

PRESSCON LOX systeem Gebruikershandleiding pagina 26

Inhoudsopgave

Advertenties

Beschikbare talen

Beschikbare talen

Nr.
Error bericht op rij 1
155
N2 flow out
156
N2 pressure
157
N2 pressure
158
N2 pressure
159
No ECD display message
160
N2 production
161
Psa valve set 1
162
Psa valve set 2
163
Psa valve set 3
164
Drain valve 1
165
Drain valve 2
166
No ECD display message
167
No ECD display message
168
Flow sensor error
169
No ECD display message
170
Air flow in
171
N2 flow out
172
N2 pressure
173
Flow out fault
174
No ECD display message
175
Air flow in
176
N2 flow out
177
N2 pressure
178
No ECD display message
179
No ECD display message
180
Wrong sensor fault
181
No ECD display message
182
No ECD display message
183
No ECD display message
184
No ECD display message
185
No ECD display message
186
No ECD display message
187
No ECD display message
188
No ECD display message
189
No ECD display message
190
No ECD display message
191
No ECD display message
192
No ECD display message
26
Error bericht op rij 2
Omschrijving
maximal
Flow out is set higher than value at this production
Sensor error
Pressure sensor not found
minimal
Pressure sensor set lower than value at this production
maximal
Pressure sensor set higher than value at this production
Reserved error
Production error, there has a fault occured through
which the N2 production is switched off
disabled
PSA valveset 1 disabled
disabled
PSA valveset 2 disabled
disabled
PSA valveset 3 disabled
disabled
Drainvalve 1 disabled
disabled
Drainvalve 2 disabled
Reserved error
Reserved error
Fault within flow sensor
Reserved error
timeout
Measurement timeout flow in
timeout
Measurement timeout flow out
timeout
Measurement timeout N2 pressure
Fault in output flow
Reserved error
disabled
Flow in disabled
disabled
Flow uit disabled
disabled
N2 pressure disabled
Reserved error
Reserved error
Fault in the number or type of sensor
Reserved error
Reserved error
Reserved error
Reserved error
Reserved error
Reserved error
Reserved error
Reserved error
Reserved error
Reserved error
Reserved error
Reserved error
Bron bericht
ERR_N2N2FLOWOUT_MAX
ERR_N2PRESSURE_NOSENSOR
ERR_N2PRESSURE_MIN
ERR_N2PRESSURE_MAX
ERR_N2RESERVED_159
ERR_N2PRODUCTION
ERR_N2PSAVALVE_DISABLED01
ERR_N2PSAVALVE_DISABLED02
ERR_N2PSAVALVE_DISABLED03
ERR_N2DRAINVALVE_DISABLED01
ERR_N2DRAINVALVE_DISABLED02
ERR_N2RESERVED_166
ERR_N2RESERVED_167
ERR_N2RESERVED_168
ERR_N2RESERVED_169
ERR_N2AIRFLOWIN_TIMEOUT
ERR_N2N2FLOWOUT_TIMEOUT
ERR_N2PRESSURE_TIMEOUT
ERR_N2RESERVED_173
ERR_N2RESERVED_174
ERR_N2AIRFLOWIN_DISABLED
ERR_N2N2FLOWOUT_DISABLED
ERR_N2PRESSURE_DISABLED
ERR_N2RESERVED_178
ERR_N2RESERVED_179
ERR_N2RESERVED_180
ERR_N2RESERVED_181
ERR_N2RESERVED_182
ERR_N2RESERVED_183
ERR_N2RESERVED_184
ERR_N2RESERVED_185
ERR_N2RESERVED_186
ERR_N2RESERVED_187
ERR_N2RESERVED_188
ERR_N2RESERVED_189
ERR_N2RESERVED_190
ERR_N2RESERVED_191
ERR_N2RESERVED_192

Advertenties

Inhoudsopgave
loading

Inhoudsopgave