Foutmeldingen van de N
Control
2
De volgende tabel toont welke fout meldingen er door de N2 control kunnen worden gegenereerd.
Nr.
Error bericht op rij 1
120
No ECD display message
121
CAN-bus extension
122
No ECD display message
123
No ECD display message
124
CAN-bus 3
125
CAN-bus 4
126
No ECD display message
127
No ECD display message
128
No ECD display message
129
No ECD display message
130
N2 master detects
131
Compressor
132
Compressor
133
Compressor
134
Compressor
135
Compressor
136
Compressor
137
Compressor
138
No ECD display message
139
No ECD display message
140
N2 master detects
141
Psa generator
142
Psa generator
143
Psa generator
144
Psa generator
145
Psa generator
146
Psa generator
147
Psa valve set 1
148
Psa valve set 2
149
Psa valve set 3
150
Air flow in
151
Air flow in
152
Air flow in
153
N2 flow out
154
N2 flow out
Error bericht op rij 2
Omschrijving
Start of device specific error
not available
Communication with CAN-extension print fault
N2Control is in manual mode
Reserved error
bus fault
CAN-bus 3 bus fault
bus fault
CAN-bus 4 bus fault
Reserved error
Reserved error
Reserved error
Reserved error
a compressor error
There is a compressor within the system with a fault
not ready
The compressor of this N2Control is not ready
The compressor of this N2Control has a fault (according
fault input active
to fault input)
not available
There is no compressor available within the system
active timeout
The compressor has not become active
producing timeout
The compressor is not producing
unload timeout
The compressor runs to long in idle (no load)
disabled
The compressor is disabled
Reserved error
Reserved error
a Psa error
There is a PSA generator within the system with a fault
PSA generator has missed to many synchronization
no sync received
messages
dryer fault
PSA generator dryer fault
compressorpressure
PSA generator compressor pressurevalve fault
beko(moisture) fault
PSA generator bekoguard fault
Dust filter fault
PSA generator dustfilter fault
Dewpoint sensor
PSA generator dew point sensor fault
settings
Settings of the master do not match with PSA 1
settings
Settings of the master do not match with PSA 2
settings
Settings of the master do not match with PSA 3
Sensor error
Flow in sensor is not found
minimal
Flow in is set lower than value at this production
maximal
Flow in is set higher than value at this production
Sensor error
Flow out sensor is not found
minimal
Flow out is set lower than value at this production
Bron bericht
ERR_N2DEVICEBASE
ERR_N2EXTENSION_NA
ERR_N2MANUALMODE
ERR_N2RESERVED_123
ERR_N2CAN3_BUSERROR
ERR_N2CAN4_BUSERROR
ERR_N2RESERVED_126
ERR_N2RESERVED_127
ERR_N2RESERVED_128
ERR_N2RESERVED_129
ERR_N2COMPRESSOR_ERROR
ERR_N2COMPRESSOR_NOTREADY
ERR_N2COMPRESSOR_FAULTINPUT
ERR_N2COMPRESSOR_NONEAVAILABLE
ERR_N2COMPRESSOR_ACTIVETIMEOUT
ERR_N2COMPRESSOR_PRODUCINGTIMEOUT
ERR_N2COMPRESSOR_UNLOADTIMEOUT
ERR_N2COMPRESSOR_DISABLED
ERR_N2RESERVED_138
ERR_N2RESERVED_139
ERR_N2PSAGENERATOR_ERROR
ERR_N2PSAGENERATOR_NOSYNCRECEIVED
ERR_N2PSAGENERATOR_DRYERFAULT
ERR_N2PSAGENERATOR_COMPAIRPRESSURESWITCH
ERR_N2PSAGENERATOR_BEKOGUARDSENSOR
ERR_N2PSAGENERATOR_DUSTFILTERSENSOR
ERR_N2PSAGENERATOR_DEWPOINTSENSOR
ERR_N2PSAVALVE_SETTINGS01
ERR_N2PSAVALVE_SETTINGS02
ERR_N2PSAVALVE_SETTINGS03
ERR_N2AIRFLOWIN_NOSENSOR
ERR_N2AIRFLOWIN_MIN
ERR_N2AIRFLOWIN_MAX
ERR_N2N2FLOWOUT_NOSENSOR
ERR_N2N2FLOWOUT_MIN
25