S1S
# Contact elektrische voeding met kWh-
voorkeurtarief
S2S
# Impulsingang 1 elektrische meter
S3S
# Impulsingang 2 elektrische meter
S4S
# Smart grid-toevoer
S6S~S9S
* Digitale ingangen vermogensbeperking
S10S-S11S
# Smart grid-laagspanningscontact
SS1 (A4P)
* Keuzeschakelaar
TR1
Voedingstransformator
X6M
# Klemmenblok elektrische voeding back-
upverwarming
X6M
* Connector elektrische voeding
boosterverwarming
X7M, X8M
Klemmenblok elektrische voeding
boosterverwarming
X10M
* Klemmenblok elektrische voeding Smart grid
X*, X*A, X*Y*, Y*
Connector
X*M
Klemmenblok
* Optioneel
# Ter plaatse te voorzien
Vertaling van tekst op bedradingsschema
Engels
(1) Main power connection
For HP tariff
Indoor unit supplied from outdoor Binnenunit gevoed door buiten
Normal kWh rate power supply
Only for normal power supply
(standard)
Only for preferential kWh rate
power supply (outdoor)
Outdoor unit
Preferential kWh rate power
supply contact: 16 V DC
detection (voltage supplied by
PCB)
SWB
Use normal kWh rate power
supply for indoor unit
(2) Backup heater power supply
Only for ***
(3) User interface
Only for remote user interface
SD card
WLAN cartridge
(4) Domestic hot water tank
3 wire type SPST
Booster heater power supply
Only for ***
SWB
Ext. thermistor(5)
SWB
Field supplied options(6)
ETBH/X12EF6V+9W
Daikin Altherma 3 H MT W
4P634879-1 – 2021.03
Vertaling
(1) Aansluiting
hoofdstroomtoevoer
Voor warmtepomptarief
Elektrische voeding met normaal
kWh-tarief
Alleen voor normale voeding
(standaard)
Alleen voor elektrische voeding
met kWh-voorkeurtarief (buiten)
Buitenunit
Contact elektrische voeding met
kWh-voorkeurtarief: 16 V-
gelijkstroomdetectie (spanning
geleverd door printplaat)
Schakelkast
Gebruik elektrische voeding met
normaal kWh-tarief voor
binnenunit
(2) Elektrische voeding back-
upverwarming
Alleen voor ***
(3) Gebruikersinterface
Alleen voor de
gebruikersinterface gebruikt als
kamerthermostaat
Kaartsleuf voor WLAN-houder
WLAN-houder
(4) Warmtapwatertank
type 3 geleiders SPST
Elektrische voeding
boosterverwarming
Alleen voor ***
Schakelkast
(5) Externe thermistor
Schakelkast
(6) Niet meegeleverde opties
10 Technische gegevens
Engels
12 V DC pulse detection (voltage
supplied by PCB)
230 V AC supplied by PCB
Bizone mixing kit
Continuous
DHW pump output
DHW pump
Electrical meters
For HV smartgrid
For LV smartgrid
For safety thermostat
For smartgrid
Inrush
Max. load
Normally closed
Normally open
Safety thermostat contact: 16 V
DC detection (voltage supplied
by PCB)
Shut-off valve
Smartgrid contacts
Smartgrid PV power pulse meter Smart Grid fotovoltaïsche
SWB
Option PCBs(7)
Alarm output
Changeover to ext. heat source
Max. load
Min. load
Only for demand PCB option
Only for digital I/O PCB option
Options: external heat source
output, solar pump connection,
alarm output
Options: On/OFF output
Power limitation digital inputs: 12
V DC / 12 mA detection (voltage
supplied by PCB)
Refer to operation manual
Solar input
Solar pump connection
Space C/H On/OFF output
SWB
(8) External On/OFF thermostats
and heat pump convector
Additional LWT zone
Vertaling
12 V-
gelijkstroompulsdetectie (spannin
g geleverd door printplaat)
230 V wisselstroom geleverd
door printplaat
Bizonemengkit
Continue stroom
Uitgang van de
warmtapwaterpomp
Warmtapwaterpomp
Elektriciteitsmeters
Voor Smart Grid op
hoogspanning
Voor Smart Grid op laagspanning
Voor veiligheidsthermostaat
Voor Smart Grid
Inschakelstroomstoot
Maximale belasting
Normaal gesloten
Normaal geopend
Contact voor de
veiligheidsthermostaat: 16 V-
gelijkstroomdetectie (spanning
geleverd door printplaat)
Afsluiter
Smart Grid-contacten
voedingspulsmeter
Schakelkast
(7) Optionele printplaten
Alarmuitgang
Omschakeling naar externe
warmtebron
Maximale belasting
Minimale belasting
Alleen voor optie vraag-printplaat
Alleen voor optie digitale I/O-
printplaat
Opties: uitgang externe
warmtebron, aansluiting
zonnepomp, alarmuitgang
Opties: uitgang AAN/UIT
Digitale inputs
vermogenbeperking: 12 V-
gelijkstroom-/12 mA-
detectie (spanning geleverd door
printplaat)
Raadpleeg de
gebruiksaanwijzing
Ingang zonnesysteem
Aansluiting zonnepomp
Uitgang ruimtekoeling/-
verwarming AAN/UIT
Schakelkast
(8) Externe AAN/UIT-
thermostaten en
warmtepompconvector
Aanvoerwatertemperatuur
secundaire zone
Installatiehandleiding