Download Inhoudsopgave Inhoud Print deze pagina

Jung FMUS2UP Bedieningshandleiding pagina 13

Verberg thumbnails Zie ook voor FMUS2UP:
Inhoudsopgave

Advertenties

eNet
eNet radiografische zender Universeel 2-voudig mini
Operating mode
Settings, channel/scene
Parameter name
Local Operation
82580833
j0082580833
Scene
1-gang switching/dimming/
Venetian blind
1-gang automatic function
2-gang switching/dimming/
Push-button operation
2-gang automatic functions
Scenes for signal contact
2-gang blind
Basic setting: Switching/dim-
ming/Venetian blind
Setting options, Basic set-
ting
On, Off
Basic setting: On
13/14
Setting of the transmission
behaviour suitable for operati-
on concept and the connected
operating elements.
Scene: 2 scene buttons. Con-
trol with push-button contacts.
1-gang switching / dimming /
Venetian blind: 1 channel,
both inputs operate the same
channel. Activation with 2
push-button contacts,
e.g. series push-button
(2-surface operation). Corres-
ponds to the setting 1-K
K7O.
1-gang automatic function:
1 channel, both inputs operate
the same channel. Control
with 2 switching contacts,
e.g. with Venetian blind clock.
Corresponds to the setting 1-K
Ø.
2-gang switching/dim-
ming/push-button operation:
2 channels, each input opera-
tes its own channel. Each con-
trol with push-button contact
(1-surface operation). Corres-
ponds to the setting 2-K
K7M.
2-gang automatic function:
2 channels, each input opera-
tes its own channel. Activation
with switching contact,
e.g. switch, motion detector,
timer. Corresponds to the set-
ting 2-K Ø.
Scenes for signal contact: E1
operates two scenes. When
closing and opening, the res-
pective scene is recalled. Con-
trol with switching contact.
2-gang Venetian blind: 2 chan-
nels, each input operates its
own channel. Control with
push-button contacts (2-surfa-
ce operation).
Explanations
Blocks the input for local ope-
ration.
27.07.2016

Advertenties

Inhoudsopgave
loading

Inhoudsopgave