eNet
Radiografische jaloezieactor, voor DIN-rail
Moving time
Minimum change-over-time
Invert movement direction
Operating hours up
Operating hours down
Information window
During channel selection in the Information window, the following settings can be made or valu-
es displayed.
Display value
Position value, venetian blind
Position value, slat
Restraint
Lock-out protection
Switching cycle counter UP
Total UP operating hours
82581813
J:0082581813
1 ... 600 sec
Basic setting: 120 s
300 ms ... 10 sec
Basic setting: 1 s
On, Off
Basic setting: Off
0...65535
Basic setting: Current value
0...65535
Basic setting: Current value
Explanations
The position value of the Venetian blind can
be changed.
The position value of the slat can be changed.
Display of forced position status.
Display of the lock-out protection status
Display of the switching cycles in the UP direc-
tion with the factor 10, e.g. the value 5 x 10 is
displayed for 50 switching cycles.
Display of the operating hours in the UP direc-
tion since the start of operation.
9/10
Absolute time which the
blind/shutter requires from the
top to the bottom end position.
The entry is essential if scene
or position movements are to
occur.
Minimum interruption time
when changing directions.
Increasing the minimum chan-
ge-over time will cause less
wear on the motors.
Inverts the activation of the
relay outputs. During inverted
operation, the relay outputs
"Up" and "Down" should be
activated in reverse. This is
required, for example, for con-
trolling skylights.
The time is counted during
which the load is physically
switched on (relay contact clo-
sed).
This parameter can be reset to
"0", for example after exchan-
ging the load.
The Reset button is used to
reset the counter to "0". The
device must be programmed
to apply the change.
The time is counted during
which the load is physically
switched on (relay contact clo-
sed).
This parameter can be reset to
"0", for example after exchan-
ging the load.
The Reset button is used to
reset the counter to "0". The
device must be programmed
to apply the change.