Download Inhoudsopgave Inhoud Print deze pagina

Zibro S1126 Gebruiksaanwijzing pagina 19

Inhoudsopgave

Advertenties

Beschikbare talen

Beschikbare talen

Warning
If the air conditioner is operating in the COOLING or DRY mode while relative humidity is over
80%, moisture may drip out of the air outlet of the indoor unit (due to a window or door being
open, for instance).
Noise
-
Install the air conditioner on a solid base in order to prevent excessive noise.
-
Install the outdoor unit in such a way that the expelled air does not cause a nuisance for neighbours.
-
Do not place obstacles in the path of the air expelled from the outdoor unit, this increases noise.
Safety features
1
The safety feature deactivates the unit in the following cases:
- When the function is stopped or changed while the unit is operating. Wait 3 minutes before
switching the air conditioner on again.
- After the plug has been inserted in the socket and the unit has been immediately switched on. The
unit will activate after approximately 20 seconds.
2.
Press the ON/OFF button to restart after the unit has deactivated due to the operation of the safety
feature. The Timer must then be reset.
Checks
The following must be checked after the air conditioner has been in use for an extended period of time:
-
Overheating of the power cable and the plug. Can you smell burning?
-
Is there more noise or vibration than normal?
-
Does the indoor unit leak water?
-
Is the metal housing live?
Switch the air conditioner off in all the above cases! We recommend periodic inspection by a registered
installer (at least once every five years).
Feature of the HEATING mode
For heating
When the HEATING function is activated, the airstream will only start to flow from the indoor unit after
2 – 5 minutes.
After Heating
When the Heating function is deactivated, the fan of the indoor unit will continue operating for another 2
– 5 minutes.
Defrosting
During HEATING, the machine will defrost automatically in order to ensure optimum operating efficiency.
This procedure usually takes 2-10 minutes. The fan function stops during defrosting. The HEATING function
restarts automatically after defrosting.
4
19

Advertenties

Hoofdstukken

Inhoudsopgave
loading

Deze handleiding is ook geschikt voor:

S1135S1153S1170

Inhoudsopgave