Operation voltage
System voltage, auto detect
Maximum output continues
Maximum output peak, 1 sec.
Voltage tolerance
Cutt-off voltages
Delay 10 seconds
Pre-warning voltages
Automatic re-start voltage, delay 10sec
Consumption in cutt-off condition
Consumption in on condition
Overvoltage protection
Features and protections
Connections
Ambient temperature
Cooling
Level of protection
Weight
Dimensions housing
12 Vdc (8-16Vdc) en 24 Vdc (16-35Vdc)
12Vdc
200 Amp.
500 Amp.
2%
Mode 1
12,5 Volt
Mode 2
12,0 Volt
Mode 3
11,5 Volt
Mode 4
11,0 Volt
Mode 5
10,5 Volt
Mode 6
10,0 Volt
Mode 1
12,8 Volt
Mode 2
12,5 Volt
Mode 3
12,0 Volt
Mode 4
11,5 Volt
Mode 5
11,0 Volt
Mode 6
10,5 Volt
13,0 Volt
25mA
244mA
16 Volt
Overvoltage portection, reverse polarity
2x M6 bolts, 2x faston (6,3x0,8mm)
SBP 200-12/24
8-35 Vdc
100 Amp.
250 Amp.
protection
-30°C untill 60°C
Convection
IP 54
100 gr.
4,8 x 4,6/7,8 x 4,6 cm
24Vdc
2%
25,0 Volt
24,0 Volt
23,0 Volt
22,0 Volt
21,0 Volt
20,0 Volt
25,6 Volt
25,0 Volt
24,0 Volt
23,0 Volt
22,0 Volt
21,0 Volt
26,0 Volt
21mA
178mA
32 Volt