Download Print deze pagina

Xenteq SBP 200-12/24 Gebruiksaanwijzing pagina 6

Advertenties

Operation voltage
System voltage, auto detect
Maximum output continues
Maximum output peak, 1 sec.
Voltage tolerance
Cutt-off voltages
Delay 10 seconds
Pre-warning voltages
Automatic re-start voltage, delay 10sec
Consumption in cutt-off condition
Consumption in on condition
Overvoltage protection
Features and protections
Connections
Ambient temperature
Cooling
Level of protection
Weight
Dimensions housing
12 Vdc (8-16Vdc) en 24 Vdc (16-35Vdc)
12Vdc
200 Amp.
500 Amp.
2%
Mode 1
12,5 Volt
Mode 2
12,0 Volt
Mode 3
11,5 Volt
Mode 4
11,0 Volt
Mode 5
10,5 Volt
Mode 6
10,0 Volt
Mode 1
12,8 Volt
Mode 2
12,5 Volt
Mode 3
12,0 Volt
Mode 4
11,5 Volt
Mode 5
11,0 Volt
Mode 6
10,5 Volt
13,0 Volt
25mA
244mA
16 Volt
Overvoltage portection, reverse polarity
2x M6 bolts, 2x faston (6,3x0,8mm)
SBP 200-12/24
8-35 Vdc
100 Amp.
250 Amp.
protection
-30°C untill 60°C
Convection
IP 54
100 gr.
4,8 x 4,6/7,8 x 4,6 cm
24Vdc
2%
25,0 Volt
24,0 Volt
23,0 Volt
22,0 Volt
21,0 Volt
20,0 Volt
25,6 Volt
25,0 Volt
24,0 Volt
23,0 Volt
22,0 Volt
21,0 Volt
26,0 Volt
21mA
178mA
32 Volt

Advertenties

loading