1. Features
Performance data of Swimming Pool Heat Pump Unit
***Refrigerant : R32
Unit
Heating Capacity (27/24,3°C)
Heating Power Input
COP
Heating Capacity (24/19°C)
Heating Power Input
COP
Heating Capacity (19/15°C)
Heating Power Input
COP
Power Supply
Compressor Quantity
Compressor
Fan Number
Fan Power Input
Fan Rotate Speed
Fan Direction
Noise
Water Connection
Water Flow Volume
Water Pressure Drop (max)
Unit Net Dimensions (L/W/H)
Unit Ship Dimensions (L/W/H)
Net Weight
Shipping Weight
Heating:
Outdoor air temp :
Outdoor air temp :
Outdoor air temp :
Operating Range:
Ambient temperature :
Water temperature :
PASRW 035-P-AH-C
kW
13.5
Btu/h
45900
kW
2.38
5.67
kW
12.2
Btu/h
41480
kW
2.31
5.28
kW
9.1
Btu/h
30940
kW
2.12
4.29
230V~/50hz
rotary
W
45
RPM
840
horizontal
dB(A)
55
mm
50
m³/h
5.3
kPa
2.8
mm
mm
kg
kg
27°C/24.3°C Inlet water temp :
24°C/19°C Inlet water temp :
15°C/12°C Inlet water temp :
-7°C / 43°C
9°C / 40°C
PASRW 040-P-AH-C
17
49640
2.44
6.96
13.1
44540
2.38
5.67
10
34000
2.25
4.44
230V~/50hz
1
1
rotary
1
1
80
830
horizontal
56
50
6.0
3
Next page
See Package label
See nameplate
See package label
26°C
26°C
26°C
MATTIMMQ
Pools