ENGLISH
equipment for proper air circulation. The front of
the unit should have enough space for smooth
adjustment of the cabinet temperature. If the
ambient temperature can exceed 38°C, allow at
least 10 cm clearance from the wall at the side of
the machine compartment to prevent overloading
and damaging the refrigeration circuit.
Air Outlet
Air Inlet
Min. 50cm
Fig. 3
2. SET UP
IMPORTANT
1. Do not tilt the unit more than 45° when
mounting the Legs or Casters.
2. Carry the unit by holding its bottom.
1) Cut the shipping band and remove the carton.
Carton
Carton (Base)
Fig. 4
2) Take out the accessory Legs or Casters.
3) Tilt the unit backward to mount the front Legs or
Casters (work in pair).
Fig. 5
4) Mount the rear Legs or Casters in the same way.
When mounting the Casters, lock the two front
Casters before mounting the rear ones, or the unit
will slide when tilted.
All manuals and user guides at all-guides.com
5) Before operating the unit, remove all shipping
6) Position the unit in a selected site.
7) Clean the interior with a soft cloth soaked in cold
8) Level the refrigerator/freezer in both the left-to-
3. SHELF AND SHELF CLIP
* The Shelf is adjustable in 1" increments. Adjust the
* To attach the Shelf Clip, insert the upper tab into
Shipping Band
4. ELECTRICAL CONNECTIONS
* This refrigerator/freezer must be plugged into
2
carton, packing, tape(s) and protective plastic film
on the exterior and Top Panel. Be careful not to
damage the exterior panels.
or warm water containing the proper amount of
neutral cleaner and wrung dry.
right and the front-to-rear directions (levelness:
within 1°).
Shelf Clips according to the height of stored items.
an adjust hole in the Shelf Post to hook the Shelf
Clip, and push the lower tab into another adjust
hole until it locks in place. To detach the Shelf Clip,
reverse the above procedure.
Shelf Clip
Fig. 6
CAUTION
Attach the Shelf Clips properly to make the
Shelf level.
IMPORTANT
This refrigerator/freezer is provided with no
power switch or earth leakage circuit breaker,
but with overcurrent protection (fuse) only.
Install a switch rated at least 10A on the main
power supply.
the separated power receptacle which is readily
a c c e s s i b l e a n d h a s e n o u g h c a p a c i t y. T h e
maximum allowable voltage variation should not
exceed ± 10 percent of the nameplate rating. See
the Nameplate.
Hook
Push
Shelf Post