1 Introduction
The pump is intended to be used as a pressur-
ized water system on yachts and small craft.
Possible other applications are pumping of flu-
ids for cleaning purposes or water purification.
In a pressurized water system the pump will
be switched on immediately after the pressure
has dropped when water is tapped ensuring a
continuous flow of tap water.
Following the recommendations below will re-
sult in a longer life and better performance of
your water pressure pump.
• Ensure that the water supply tank is always
full; although the pump can still run when
dry, this will prevent unnecessary dry run-
ning.
• Check that the battery voltage is correct.
Battery voltage loss can be reduced by us-
ing cables of sufficient cross sectional area.
• Ensure that the pressurized water system
is properly prepared for winter before the
temperature falls below zero. Otherwise,
irreparable damage may be caused to the
system.
• Carry out the maintenance described regu-
larly.
8
050406 .01
All manuals and user guides at all-guides.com
2 Installation
2.1 General
Always install the pump in accordance with
the applicable regulations of the country con-
cerned.
2.2 Position
• See '9 Installation recommendations' on
• The space in which the tank is placed should
• Position the pump in such a way that it is
• There must be sufficient free space available
• Also ensure that there is sufficient free
• Make sure that the foundation for the pump
vetus® Automatic demand water pressure pump WP
pages 46 and 47.
1 The pump may be positioned at the
same level or lower or higher as the tank;
the maximum priming height is is 1.8 m
(6 ft).
2 The maximum suction line length (hori-
zontally) is 9 m (30 ft).
3 The pump can be mounted in any posi-
tion. The pump head should be pointing
downwards if mounted vertically.
be dry and properly ventilated. The pump
should be 1 cm (3/8") free all round from
bulkheads or other equipment, to provide
ventilation. Do not locate the pump in a
space less than 0.03 m
foot) unless adequate ventilation is pro-
vided. In case of overheating the integrated
thermal protection will interrupt operation.
When cooled down sufficiently the pump
will resume operation.
readily accessible for inspection.
to perform maintenance on the pump.
space for the hose connections. These must
be easily accessible during installation.
is strong enough to secure it properly.