Download Inhoudsopgave Inhoud Print deze pagina

Hilti SJD 6-A22 Originele Handleiding pagina 31

Inhoudsopgave

Advertenties

Trouble or fault
The saw blade drops out.
The saw blade cannot be
inserted.
The orbital action cannot be
adjusted.
The orbital action doesn't
work.
The battery runs down more
quickly than usual.
The battery doesn't engage
with an audible click.
1 LED blinks.
The power tool does not
work.
All 4 LEDs blink.
The power tool does not
work.
The power tool or battery
gets very hot.
12
Disposal
WARNING
Risk of injury due to incorrect disposal! Health hazards due to escaping gases or liquids.
▶ DO NOT send batteries through the mail!
▶ Cover the terminals with a non-conductive material (such as electrical tape) to prevent short circuiting.
▶ Dispose of your battery out of the reach of children.
▶ Dispose of the battery at your Hilti Store, or consult your local governmental garbage disposal or public
health and safety resources for disposal instructions.
Most of the materials from which Hilti products are manufactured can be recycled. The materials must be
correctly separated before they can be recycled. In many countries, your old tools, machines or appliances
can be returned to Hilti for recycling. Ask Hilti Service or your Hilti sales representative for further information.
▶ Do not dispose of power tools, electronic equipment or batteries as household waste!
13
RoHS (Restriction of Hazardous Substances)
Click on the links to go to the table of hazardous substances: qr.hilti.com/r5212958
*2149486*
Possible cause
The saw blade is not correctly en-
gaged.
The clamping system is clogged
with foreign matter.
The clamping system is clogged
with foreign matter.
Foreign matter in the orbital-action
adjusting lever groove.
The orbital-action mechanism is
clogged with foreign matter.
The orbital-action adjusting lever is
in position "0".
Very low ambient temperature.
The retaining lugs on the battery
are dirty.
Battery is discharged.
The battery is too hot or too cold.
The tool has been overloaded.
Electrical fault.
2149486
Action to be taken
▶ Repeat the insertion procedure.
▶ Make sure that the blade holder
is fully open and that the saw
blade is pushed all the way in
against the spring resistance.
▶ Clean out the blade holder.
▶ Clean out the blade holder.
▶ Clean out the orbital-action
adjusting lever groove.
▶ Check whether foreign matter
is present in the area of the
orbital-action fork and clean it
out.
▶ Adjust it to the desired setting.
▶ Allow the battery to warm up
slowly to room temperature.
▶ Clean the retaining lugs and refit
the battery.
▶ Change the battery and charge
the empty battery.
▶ Allow the battery to cool down
or warm up slowly to room
temperature.
▶ Release the on/off switch and
then press it again. Then allow
the power tool to run under no
load for approx. 30 seconds.
▶ Switch the power tool off im-
mediately, remove the battery,
keep it under observation, allow
it to cool down and contact Hilti
Service.
English
25

Advertenties

Inhoudsopgave
loading

Inhoudsopgave