ADVANCED MENU
This menu controls the advanced parameters of the charger.
To move from one parameter to another push the Select key :
Activation «Change battery» > Activation «Power Supply» > Activation «Expert Curve» (> Adjusment of the
SELECT
«Expert Curve» parameters)
• CHANGE BATTERY mode activation:
To activate the CHANGE BATTERY mode, select «ADVANCED MENU |
Change bat: ON». Now this mode will be accessible from the mode list.
• POWER SUPPLY mode activation:
To activate the POWER SUPPLY mode, select «ADVANCED MENU | Power
Supply: ON». Now this mode will be accessible from the mode list.
• «EXPERT» curve activation:
To activate the «RECOV» curve, select «ADVANCED MENU | Expert curve:
ON». Now this curve will be available in the charging curves list from the
CHARGE mode.
• Parameters adjustment of the «Expert» curve:
If the charging curve is activated, the charging curve parameters can be
adjusted (type IU
I
U):
0
0
- Unominal: Battery nominal voltage (6V, 12V or 24V).
- Ucharge: Charge voltage adjustable from 6.0 to 30.0V (Step 7).
- Urecovery: Recovery voltage adjustable up to 30.0V.
If the value «OFF» is selected the recovery function is inactive (Step 2
and 4).
- Ufloating: Floating voltage adjustment.
If the value «OFF» is selected the floating function is inactive (Step 9).
- Trecovery: Maximum time for shorted cells recovery, adjustable from
1h to 12h (Step 2).
- Trefresh: Time for the refreshing phase adjustable from 1h to 12h. If
the value «OFF» is selected, the refresh function is not activated (Step 8).
- T desulfat : Maximum time of the desulfation phase adjustable from 1h
to 12h (Step 4).
- T ch_max: Maximum charging time (Step 7 and 6).
- T ch_min: Minimum charging time (Step 7 and 6).
- Urefresh: Maximum voltage during refresh (Step 8).
- OCP (Over Charge Protection): Maximum percentage of the nominal
capacity that can be injected before protection.
aWarning:
When charging in-situ, a «Urecovery» or «Urefresh» too high
might damage the electronics of the vehicle. We advise NOT to
adjust these settings above 15V.
To save and validate the new settings, select «ADVANCED MENU» | save? Yes»
Push the «MODE» key to exit the «Configuration» menu.
GYSFLASH 30.24 HF
ADVANCED MENU
ON
ADVANCED MENU
Change bat.:
OFF
OFF
ON
ADVANCED MENU
Power Supply: OFF
OFF
ON
ADVANCED MENU
expert curve:
OFF
OFF
OFF
ON
6V
EXPERT CURVE
12V
Unominal:
12V
24V
6.0V
12.0V
24.0V
EXPERT CURVE
6.1V
12.1V
24.1V
...
...
Ucharge:
14.3V
8.0V
16.0V
30.0V
OFF
OFF
OFF
Uch
Uch
Uch
EXPERT CURVE
...
...
Urecovery:
OFF
29.9V
29.9V
29.9V
30.0V
30.0V
30.0V
OFF
OFF
OFF
6.0V
12.0V
24.0V
EXPERT CURVE
6.1V
12.1V
24.1V
U oating:
OFF
...
...
Uch
Uch
Uch
1h
EXPERT CURVE
2h
...
T recovery:
5h
12h
1h
EXPERT CURVE
2h
...
T desulfat:
12h
12h
1h
EXPERT CURVE
2h
...
Tch_max:
16h
36h
0h
EXPERT CURVE
1h
...
Tch_min:
0h
Tch_max
OFF
1h
EXPERT CURVE
2h
T refresh:
5h
...
12h
Uch
EXPERT CURVE
...
30.9V
U refresh:
17.0V
31.0V
100%
EXPERT CURVE
...
245%
OCP:
200%
250%
Yes
ADVANCED MENU
Save?
No
No
RETURN
EN
...
...
...
19